Update the HE regulatory information AP types based on IEEE
P802.11-REVme/D4.0. Set the default AP type to VLP. Check for valid
values when setting 'he_6ghz_reg_pwr_type' in the interface
configuration.
Signed-off-by: Ilan Peer <ilan.peer@intel.com>
The location of the comment is incorrect and it is not really needed.
Remove it.
Signed-off-by: Benjamin Berg <benjamin.berg@intel.com>
Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
We only print the newline if the AP MLD ID is present
(BASIC_MULTI_LINK_CTRL_PRES_AP_MLD_ID), fix that.
Fixes: e3e68668c1 ("ctrl_iface: Report RNR and ML in BSS command")
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
It is not really helpful to get debug prints about Hotspot 2.0 frame
filtering when trying to connect a non-Hotspot 2.0 network. Remove this
debug print that was being printed for every connection that did not use
Hotspot 2.0.
Signed-off-by: Jouni Malinen <j@w1.fi>
In cases of SAE failure and testing, mgmt->sa was used for sending the
Authentication frame. Fix these to use the station address (which is
the MLD MAC address in cases of non-AP MLDs).
Signed-off-by: Ilan Peer <ilan.peer@intel.com>
Add a testing configuration such that the AP would be reported as
disabled in the RNR TBTT information MLD parameters included by other
affiliated APs of the AP MLD.
Signed-off-by: Ilan Peer <ilan.peer@intel.com>
An affiliated AP of an AP MLD can temporarily be disabled. Other
affiliated APs of the AP MLD indicate this in the Reduced Neighbor
Report (RNR) elements added to their Beacon and Probe Response frames.
When an affiliated AP is disabled, it should be included in the
association exchange, but can be activated only after it is enabled.
Add support identifying disabled APs and propagate the information
to the driver within the associate() callback.
Signed-off-by: Ilan Peer <ilan.peer@intel.com>
Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
Some of these can take close to the previously used timeouts and this
could result in reporting failures in cases that worked fine.
Signed-off-by: Jouni Malinen <j@w1.fi>
Add support for overriding EHT Operation element puncturing mask
for testing purposes.
Signed-off-by: Ilan Peer <ilan.peer@intel.com>
Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
Test EHT connection on the 5 GHz band with channel bandwidths 20-160 MHz
and up to 320 MHz on the 6 GHz band.
Signed-off-by: Ilan Peer <ilan.peer@intel.com>
Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
STA EHT MCS and NSS set field size shouldn't depend on AP HE operation
channel width. Fix it.
Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
Don't ever return -1 from print_bss_info() as that causes
corruption of the output.
Also don't return -1 from print_fils_indication() as that
would stop the iteration over all BSSs.
Signed-off-by: Ilan Peer <ilan.peer@intel.com>
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
If the interface initialization fails, no links might be set when
calling the deinit functions. Those functions need to be prepared for
bss->n_links being 0.
Fixes: 859cbc396f ("nl80211: Remove links when stopping AP MLD in hostapd")
Signed-off-by: Jouni Malinen <j@w1.fi>
If the interface initialization fails, no links might be set when
calling the deinit functions. Those functions need to be prepared for
bss->flink being NULL.
Fixes: 47269be36e ("nl80211: Refactor i802_bss to support multiple links")
Signed-off-by: Jouni Malinen <j@w1.fi>
This avoids issues with old scan results from a previous test causing
incorrect association after WPS exchange.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Add a vendor attribute for EHT testbed STA to configure the
SCS traffic description support in the EHT capabilities of an
Association Request frame.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This is an event indicating to the user space firmware page fault
summary report that the driver has generated from firmware indications.
This summary report is used to analyze major cause of page faults and
associated debug information.
Signed-off-by: Mukul Sharma <quic_mukul@quicinc.com>
Add a new hostapd configuration parameter sae_password_file to read SAE
passwords (i.e., the entries that use the previously added sae_password
parameter) from a separate file.
sae_password_file uses the following format for storing passphrases:
<password/credential>[|mac=<peer mac>][|vlanid=<VLAN ID>]
[|pk=<m:ECPrivateKey-base64>][|id=<identifier>]
Examples:
<password>
<password>|id=<pw identifier>
<password>|mac=02:03:04:05:06:01|vlanid=1
<password>|vlanid=3|id=<pw identifier>
Signed-off-by: Shiva Sankar Gajula <quic_sgajula@quicinc.com>
This is needed to work around some issues that show up mainly in testing
scenarios when the same BSSID might be used with different
configurations and the scan results from the driver might include both
the old and new contents when two different SSIDs are used.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Reorder the Element ID List to fill in the values in increasing order to
match the way the Element ID List is defined.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Use AP MLD address instead of BSSID for PWE derivation during MLO
connection. This was already done for H2E in commit e869fdfeef
("wpa_supplicant: Use MLD address in SAE authentication"). While IEEE
P802.11be requires H2E to be used, there are deployed AP MLDs that do
not follow that requirement. This change to the hunting-and-pecking loop
case is needed for interoperability workarounds with such APs.
Signed-off-by: Veerendranath Jakkam <quic_vjakkam@quicinc.com>
Currently while deciding to create a new Multiple BSSID element based on
the condition when the length reaches 255, the length value being used
is the total element length (including the length of the Element ID and
Length fields as well). However, the value in the length field denotes
the number of octets following it and excluding itself. Hence including
the total length is wrong. This leads to incorrect count of Multiple
BSSID elements.
And while filling the data, the length is considered porperly as it
should be hence we are filling more data in a single go and all data is
filled in MBSSID count which is less than originally calculated. This
ultimately leads to incorrect length calculation during nla_put() and
setting the beacon to the driver fails while putting the Multiple BSSID
element data into the netlink socket buffer.
Fix this issue by considering the length excluding the Element ID and
Length field sizes.
Signed-off-by: Aditya Kumar Singh <quic_adisi@quicinc.com>
Share VLAN info in RRB when the driver advertises support for VLAN
offload (WPA_DRIVER_FLAGS_VLAN_OFFLOAD). sta->vlan_desc is unused in
this case, only sta->vlan_id is used. Skip the checks that are based on
sta->vlan_desc.
Signed-off-by: Sai Pratyusha Magam <quic_smagam@quicinc.com>
The previous timeout allowed only a single chirping round, and sometimes
not even that full round. That resulted in test failures for cases where
there was not really any incorrect behavior.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Stop dev[0] from trying to associate at the end of the test case to
reduce risk for leaving out some pending operations that could mess up
the following test case.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Handle the cases where the first attempt to start scan fails due to an
ongoing scan. Stop such scan and try again instead of failing the test
case immediately.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This avoids race conditions with UML time-travel where some cases ended
up not reporting the DPP-TX-STATUS event and that resulted in discarding
events that are more important to verify for correct behavior.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
One of the sigma_dut testing cases missed the t.join() call to make
surte the separate thread terminated. This could result in confusing
"unexpected stdout output" in a middle of an unrelated test case.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Stop and restart P2P_FIND on dev[1] to avoid timing issues where the
wait on dev[1] makes the test case fail even though this was trying to
verify that dev[0] is reacting quickly enough.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This helper is of no real use anymore, so get rid of it. This completes
send_and_recv*() cleanup. What remains is the most generic
send_and_recv() and two wrappers for it to cover the most common simpler
cases.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This is a variant for the second most common case of send_and_recv() needs:
send a command with a special response handling.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This is a variant for the most common case of send_and_recv() needs:
send a command without needing a special response handling. In addition,
move the helper functions into driver_nl80211.h since these are now
simple wrappers for the more flexible send_and_recv().
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This is not really that helpful as a separate helper function, so get
rid of one of the many send_and_recv() variants.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This is not helpful as a separate helper function anymore, so get rid of
one of the many send_and_recv() variants.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This is independent of the NL80211_ATTR_SOCKET_OWNER use, so add these
attributes from a separate helper function that is called only from
locations that actually start an operation that uses EAPOL frames.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Doing this based on driver support for control port RX or SAE seems like
undesired extra complexity. Just use this in all cases where the special
handle for a longer term operation, like connection or AP mode
operation, is needed.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This is a step towards cleaning up all the workarounds that have showed
up over the years and made the design difficult to understand. This
removes use of the separate registration of process_bss_event() as
NL_CB_VALID for the individual commands since the use of the appropriate
cb (i.e., the one from nl80211_init_bss() in these cases) will already
point to the correct handler.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This is a workaround for some race conditions where the hardcoded use of
global->nl_cb in send_and_recv() ends up getting events delivered
through unexpected context when they happen to arrive at the time when a
command is being processed.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>