Traceback (most recent call last):
File "/usr/bin/netbox_agent", line 33, in <module>
sys.exit(load_entry_point('netbox-agent==0.7.1', 'console_scripts', 'netbox_agent')())
File "/opt/netbox-agent/lib/python3.6/site-packages/netbox_agent/cli.py", line 50, in main
return run(config)
File "/opt/netbox-agent/lib/python3.6/site-packages/netbox_agent/cli.py", line 43, in run
server.netbox_create_or_update(config)
File "/opt/netbox-agent/lib/python3.6/site-packages/netbox_agent/server.py", line 417, in netbox_create_or_update
self.inventory.create_or_update()
File "/opt/netbox-agent/lib/python3.6/site-packages/netbox_agent/inventory.py", line 550, in create_or_update
self.do_netbox_disks()
File "/opt/netbox-agent/lib/python3.6/site-packages/netbox_agent/inventory.py", line 420, in do_netbox_disks
disks = self.get_hw_disks()
File "/opt/netbox-agent/lib/python3.6/site-packages/netbox_agent/inventory.py", line 344, in get_hw_disks
size = int(disk.get('size', 0))
TypeError: int() argument must be a string, a bytes-like object or a number, not 'NoneType'
```
This patch brings some of the physical and virtual drive attributes as
`custom_fields` to the disks inventory.
The goal is to have this information present to ease disks maintenance
when a drive becomes unavailable and its attributes can't be read anymore
from the RAID controller.
It also helps to standardize the extended disk attributes across the
different manufacturers.
As the disk physical identifers were not available under the correct
format (hexadecimal format using the `xml` output as opposed as `X:Y:Z` format
using the default `list` format), the command line parser has been
refactored to read the `list` format, rather than `xml` one in the
`omreport` raid controller parser.
As the custom fields have to be created prior being able to register
the disks extended attributes, this feature is only activated using the
`--process-virtual-drives` command line parameter, or by setting
`process_virtual_drives` to `true` in the configuration file.
The custom fields to create as `DCIM > inventory item` `Text` are described
below.
NAME LABEL DESCRIPTION
mount_point Mount point Device mount point(s)
pd_identifier Physical disk identifier Physical disk identifier in the RAID controller
vd_array Virtual drive array Virtual drive array the disk is member of
vd_consistency Virtual drive consistency Virtual disk array consistency
vd_device Virtual drive device Virtual drive system device
vd_raid_type Virtual drive RAID Virtual drive array RAID type
vd_size Virtual drive size Virtual drive array size
In the current implementation, the disks attributes ore not updated: if
a disk with the correct serial number is found, it's sufficient to
consider it as up to date.
To force the reprocessing of the disks extended attributes, the
`--force-disk-refresh` command line option can be used: it removes all
existing disks to before populating them with the correct parsing.
Unless this option is specified, the extended attributes won't be
modified unless a disk is replaced.
It is possible to dump the physical/virtual disks map on the filesystem under
the JSON notation to ease or automate disks management. The file path has to
be provided using the `--dump-disks-map` command line parameter.
- Added an option to specify an SSL CA certificates file to talk to the
Netbox API
- Enhanced GPU expansion bays inventory: internal GPU (VGA) goes into
the blade, external GPU (3D) goes into the expansion bay
- Unified the way expansion bays are managed (GPU and drive exansion
bays)
- Started to refactor `network` module to make it more readable
- Dependencies in `setup.py` now reads its requirements from
`requirements.txt` to avoid double maintenance
This patch adds the ability to detect and manage GPU and Disk expansion
bays, and either add their internal components into the device
corresponding to the blade server, or into a dedicated device.
It takes advantage of the work made by @cyrinux on GPU bays management, and
applies the same principle to the external disk bays, but harmonize the
inventory management:
- If no argument is specified on the command line, the GPU cards, RAID
controllers and their attached disks are added in the blade device,
and the device corresponding to an expansion device is deleted.
- If the `--expansion-as-device` option is specified on the command
line, a dedicated device corresponding to the expansion bay is
created, and the GPUs, RAID card and attached disks are removed from
the blade device and added to the expansion device.
Add ability to create Virtual Machine in netbox with an auto-detecting feature (currently VirtualBox, Xen, Hyper-V, VMWare, GCP)
One caveat, I made the choice not to report the disk as Netbox model allow only one size but VM often have multiples.
Also, lot of code refactoring to be able to use create_or_update function style, fixing a lot of corner case
Several minor fixes:
- raid_array check should return an empty array, not NoneType
- not all systems will have IPv6 defined, handle this case
- Vendor Supermicro was incomplete.