Commit graph

7 commits

Author SHA1 Message Date
Christophe Simon
e789619b34 Added disks extended attributes
This patch brings some of the physical and virtual drive attributes as
`custom_fields` to the disks inventory.

The goal is to have this information present to ease disks maintenance
when a drive becomes unavailable and its attributes can't be read anymore
from the RAID controller.

It also helps to standardize the extended disk attributes across the
different manufacturers.

As the disk physical identifers were not available under the correct
format (hexadecimal format using the `xml` output as opposed as `X:Y:Z` format
using the default `list` format), the command line parser has been
refactored to read the `list` format, rather than `xml` one in the
`omreport` raid controller parser.

As the custom fields have to be created prior being able to register
the disks extended attributes, this feature is only activated using the
`--process-virtual-drives` command line parameter, or by setting
`process_virtual_drives` to `true` in the configuration file.

The custom fields to create as `DCIM > inventory item` `Text` are described
below.

    NAME            LABEL                      DESCRIPTION
    mount_point     Mount point                Device mount point(s)
    pd_identifier   Physical disk identifier   Physical disk identifier in the RAID controller
    vd_array        Virtual drive array        Virtual drive array the disk is member of
    vd_consistency  Virtual drive consistency  Virtual disk array consistency
    vd_device       Virtual drive device       Virtual drive system device
    vd_raid_type    Virtual drive RAID         Virtual drive array RAID type
    vd_size         Virtual drive size         Virtual drive array size

In the current implementation, the disks attributes ore not updated: if
a disk with the correct serial number is found, it's sufficient to
consider it as up to date.

To force the reprocessing of the disks extended attributes, the
`--force-disk-refresh` command line option can be used: it removes all
existing disks to before populating them with the correct parsing.
Unless this option is specified, the extended attributes won't be
modified unless a disk is replaced.

It is possible to dump the physical/virtual disks map on the filesystem under
the JSON notation to ease or automate disks management. The file path has to
be provided using the `--dump-disks-map` command line parameter.
2022-03-02 15:53:38 +01:00
Christophe Simon
2f09cf8d42 Manage blade expansions as independent devices
This patch adds the ability to detect and manage GPU and Disk expansion
bays, and either add their internal components into the device
corresponding to the blade server, or into a dedicated device.

It takes advantage of the work made by @cyrinux on GPU bays management, and
applies the same principle to the external disk bays, but harmonize the
inventory management:

- If no argument is specified on the command line, the GPU cards, RAID
  controllers and their attached disks are added in the blade device,
  and the device corresponding to an expansion device is deleted.
- If the `--expansion-as-device` option is specified on the command
  line, a dedicated device corresponding to the expansion bay is
  created, and the GPUs, RAID card and attached disks are removed from
  the blade device and added to the expansion device.
2022-02-14 14:37:02 +01:00
Cyrinux
683e6cacb1
Fix HP raid controller parsing (#131)
* Some messages about the cache for example, with indentation level 0 break the parsing.
I ignore line indentation if indentation level and line dont match REGEXP_CONTROLLER_HP.

```bash

DC1|server-01:~# hpacucli ctrl all show detail

Smart Array P244br in Slot 0 (Embedded)
A cache backup failure has occurred. Please execute the "reenablecache" command
to enable the cache. Your controller may require a reboot after the operation
to complete the cache recovery process.

   Bus Interface: PCI
   Slot: 0
   Serial Number: PDZVU0WLM241FP
   Cache Serial Number: PDZVU0WLM241FP
   RAID 6 (ADG) Status: Enabled
   Controller Status: OK
   Hardware Revision: B
   Firmware Version: 7.00-0
   ...
```

* Remove whitespace
2020-06-10 15:24:43 +02:00
ramnes
bab2d26ad0 Setup tests 2020-02-02 20:24:01 +01:00
Solvik
d402b5620c
add omreport RAID support (#69) 2019-09-10 11:44:23 +02:00
ThomasADavis
b7b22ae316 use lshw for inventory (#58)
* Use lshw for inventory
* Add motherboard to inventory
* Handle non raid devices
* Handle nvme drives
2019-09-05 15:13:36 +02:00
Solvik
de3c59a675
Local inventory (#16)
- Create and update CPU
- Create and update Memory
- Create and update RAID Cards (HP and Storcli)
- Create and update Physical disks
2019-08-26 16:54:48 +02:00