Commit graph

14369 commits

Author SHA1 Message Date
Jouni Malinen
2e5397d5db tests: Create radio for p2ps_channel_active_go_and_station_different_mcc
Instead of relying on existing configuration (which may conflict
with other tests) and skipping otherwise, create a new radio with
two channels in this test and use it.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-05 02:12:00 +02:00
Johannes Berg
d25f16e478 tests: Create radio for p2ps_channel_both_connected_different_mcc
Instead of relying on existing configuration (which may conflict
with other tests) and skipping otherwise, create a new radio with
two channels in this test and use it.

Signed-off-by: Johannes Berg <johannes.berg@intel.com>
2019-02-05 02:06:36 +02:00
Jouni Malinen
d5cac05952 tests: Multi-BSSID test cases with python3
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 20:03:29 +02:00
Jouni Malinen
200ac5daf6 tests: Encode Disconnect-Request attributes in sorted order for python3
This is needed to fix issues with dict iteration resulting in different
order of attributes when trying to calculate Message-Authenticator
externally to pyrad.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 20:03:29 +02:00
Jouni Malinen
55845e190b tests: Clean up pyrad test cases for python3 compatibility
All other test cases seem to work, but radius_das_disconnect_time_window
is still failing due to incorrect authenticator or Message-Authenticator
in Disconnect-Request.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 20:03:29 +02:00
Jouni Malinen
a68e9b6980 D-Bus: Fix P2P DeleteService dict iteration
The previous implementation assumed the first entry coming out from the
dict is always service_type. That may not be the case, so properly
iterate over all dict entries in one loop instead of assuming what the
first entry is.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 17:13:54 +02:00
Jouni Malinen
366ada0412 tests: Decode sigma_dut output for python3
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 16:48:22 +02:00
Jouni Malinen
37df1775ad tests: Read sigma_dut-ap.conf as binary data for python3 compatibility
Sending UTF-8 encoded data to logger file is currently not working
properly, so create a separate binary file with a copy of
sigma_dut-ap.conf instead to work with both python2 and python3.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 16:46:31 +02:00
Jouni Malinen
e50c58e585 tests: Replace file() with open() to work with python3
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 16:11:42 +02:00
Jouni Malinen
c37ef330d0 tests: MAC address ASCII string generation in python3 compatible manner
Use struct.unpack() to get a list of int and then generate a list of
hexstr octets from it for ':'.join() to get consistent behavior for both
python2 and python3.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:35 +02:00
Jouni Malinen
0607346f12 D-Bus: Fix a memory leak in DeleteService handler
If the service_type string entry is not included, the dict entry was not
cleared.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:35 +02:00
Masashi Honma
b723b25926 tests: Replace dict.has_key() with the in operator for python3
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:35 +02:00
Masashi Honma
4aa2336ed5 tests: Use binary mode for writing WPS attributes
This is needed for python3.

Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:34 +02:00
Masashi Honma
59aecb1c42 tests: Decode StreamRequestHandler read for python3
WPSAPHTTPServer class needs to explicitly decode the read value from
a bytes object to a str object.

Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:34 +02:00
Masashi Honma
732b76139a tests: Decode upnp_soap_action() response for python3
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:34 +02:00
Masashi Honma
69f58282bc tests: ElementTree string representation in python3 compatible manner
Use ET.tostring() to avoid implicit bytes/str conversion issues within
ET implementation. Add XML declaration separately to match previous
behavior.

Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:34 +02:00
Masashi Honma
308ecbc16e tests: urlopen() compatibility for python3
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:34 +02:00
Jouni Malinen
b7da11fd95 tests: Extend build_wsc_attr() to accept both bytes and str objects
This is needed for python3.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:34 +02:00
Jouni Malinen
786ce912ce tests: Fix struct.unpack() call for a single octet with python3
python3 needs this to be a bytes object, not the first octet of that
object.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:34 +02:00
Jouni Malinen
fd86ea402e tests: Remove forgotten development time print
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:34 +02:00
Masashi Honma
27a7e75651 tests: Open Hotspot 2.0 icon files in binary modes for python3
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:34 +02:00
Masashi Honma
c4e333fa43 tests: Encode/decode base64 operations for python3
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:34 +02:00
Jouni Malinen
5c9ba3412d tests: python3 compatible way of importing gobject for D-Bus testing
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:34 +02:00
Jouni Malinen
236bbda8e4 tests: Use floor division (//) to avoid issues with python3
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:34 +02:00
Masashi Honma
4d364d9ee0 tests: Decode Popen output in wmediumd test sets for python3
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:34 +02:00
Jouni Malinen
c45b969d6a tests: python3 compatible str/bytes ord()
Need to skip ord() for python3 when going through bytes object (instead
of str object in python2).

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:34 +02:00
Jouni Malinen
95d013f530 tests: Replace str.translate() with str.replace()
This is needed for python3 since the two argument version of
str.translate() is not available for unicode. Furthermore, these cases
of delete colons from the string are simple enough for replace.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:34 +02:00
Masashi Honma
edab6c9dac tests: Fix erp_home_realm_oom error on python3
Only python3 warns to this bug.

TypeError: '>' not supported between instances of 'type' and 'int'
Exception: '>' not supported between instances of 'type' and 'int'

Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:34 +02:00
Jouni Malinen
b3361e5dc9 tests: Explicit str/bytes conversion for key_lifetime_in_memory
This is needed for python3.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:34 +02:00
Jouni Malinen
a42ec6611c tests: Explicit str/bytes conversion in sigma_dut_venue_url
This is needed for python3.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:34 +02:00
Masashi Honma
e1810300c9 tests: Replace str.decode('hex') with binascii.unhexlify() for python3
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:34 +02:00
Masashi Honma
54c58f29c0 tests: Replace str.encode('hex') with binascii.hexlify() for python3
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:34 +02:00
Masashi Honma
1c48c9bcf9 tests: Decode Popen() output for python3
Need to do this to avoid issues with following operations that assume
the output to be a str object.

Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:34 +02:00
Masashi Honma
15dfcb69df tests: Use 'b' prefix to mark Bytes literals explicitly for python3
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:33 +02:00
Masashi Honma
d5e6ffd661 tests: Decode subprocess.check_output() return value for python3
Explicit conversion to str is needed here for python3 compatibility.

Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:33 +02:00
Masashi Honma
1cfaecf70e tests: rfkill with python3 compatible version
Update rfkill helpers to not depend on python2 implicit conversions.

Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:33 +02:00
Masashi Honma
a3e00682ab tests: nl80211 attr with python3 compatible version
Update nl80211 attribute building helpers to not depend on
python2 implicit conversions.

Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:33 +02:00
Masashi Honma
e285418bed tests: HWSimController class with python3 compatible version
Update class HWSimController and netlink helpers to not depend on
python2 implicit conversions.

Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:33 +02:00
Masashi Honma
f94df3c0b0 tests: Explicitly encode str to bytes when needed for python3
Avoid implicit conversion errors when constructing bytes objects or
passing a str object to a function that needs a bytes object.

Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:33 +02:00
Masashi Honma
a444a6d262 tests: Fix failure for WPA-EAP-SUITE-B-192 key_mgmt
The wpas_config_file_key_mgmt fails with this error if wpa_supplicant is
built without CONFIG_SUITEB192=y:

Exception: SET_NETWORK failed
Exception: SET_NETWORK failed

Skip the WPA-EAP-SUITE-B-192 case if it is not supported in
wpa_supplicant so that the rest of the key_mgmt test coverage is
included.

Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:33 +02:00
Masashi Honma
cc02ce96cf tests: Explicit str/bytes conversion for socket operations for python3
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:33 +02:00
Jouni Malinen
6395b9eb3e tests: Read binary file in add_log_file() for python3
python3 requires sqlite3.Binary() input to be bytes instead of str, so
open the files for binary mode reading.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:33 +02:00
Jouni Malinen
2a79a8ce14 tests: Convert tshark output to string object for python3
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:33 +02:00
Masashi Honma
7ab74770e7 tests: Convert binascii.hexlify() output to a string object for python3
This is needed in cases the hexlify() output is used to concatenate with
a string or used in string comparisons.

Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:33 +02:00
Jouni Malinen
3a833d95b3 wpaspy: Convert to/from str to bytes as needed for python3
The control interface commands use mostly ASCII or UTF-8 strings, so
convert input/output to strings/bytes as needed for the socket
operations with python3.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-04 12:26:33 +02:00
Masashi Honma
04fa9fc7fd tests: Decode Popen() output values for python3
Explicit conversion to str is needed here for python3 compatibility.

Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-04 12:26:33 +02:00
Jouni Malinen
45b0b88f80 tests: Decode command execution output to a str for python3
Need to convert from bytes to str to allow the following string
operations to work with python3.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-02 12:51:13 +02:00
Jouni Malinen
58be42b264 tests: Remove trailing semicolons from python code
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-02 12:10:53 +02:00
Masashi Honma
9c06eda01c tests: Use python3 compatible libraries
This patch is made by using 2to3 command with some modifications.

$ find . -name *.py | xargs 2to3 -f imports -w -n

Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
2019-02-02 12:03:04 +02:00
Jouni Malinen
2974633d0c tests: Remove unused import statements
These were not used at all and caused unnecessary operations and in some
cases, compatibility issues with python3.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-02-02 11:35:13 +02:00