The part about checking the supported curves from the peer depends on
CONFIG_DPP3 and this test case needs to be skipped without that.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Prepare for an implementation change for the PB discovery channel list.
Move the standlone (not an AP) PB Configurators to a preferred channel
and enable Configurator connectivity indication in APs that act as PB
Configurators.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
These were testing only of SAE, not SAE-PK capability, and needs to be
skipped in SAE-PK is not included in the build.
Signed-off-by: Jouni Malinen <j@w1.fi>
BoringSSL is known not to support this option, so skip it to allow rest
of the test case to be performed without known failures.
Signed-off-by: Jouni Malinen <j@w1.fi>
The first sock.recv() may return both the status,RUNNING and the
following status line if the sigma_dut process ends up being faster in
writing the result than the test script is in reading the result. This
resulted in unexpected behavior and odd error messages when parsing the
result in the test cases. Fix this by dropping the status,RUNNING line
from the result in case the buffer includes multiple lines.
Signed-off-by: Jouni Malinen <j@w1.fi>
This is needed to avoid test failures when a previous test case might
have restricted the set of allowed SAE groups.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Now that wpa_supplicant does this internally as a part of the FLUSH
command, there is no need for the test scripts to try to clear the
parameter between test cases.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This test case was missing an explicit CAPI ap_reset_default and that
could result in hostapd being left running at the end of the test case.
This could result in issues with following test cases if they used a new
radio interface from HWSimRadio().
Signed-off-by: Jouni Malinen <j@w1.fi>
These commands were being issues to incorrect wpa_supplicant instance
and were missing clearing of the MAC_RAND_SCAN parameter.
Signed-off-by: Jouni Malinen <j@w1.fi>
It was possible for these test cases to fail if the first scan iteration
did not find the AP since the 10 second timeout was small enough to
terminate the second attempt before fetching the scan results. Increase
this timeout to allow at least two full scan iterations to be completed
before declaring failure.
Signed-off-by: Jouni Malinen <j@w1.fi>
Update the SAE-PK implementation to match the changes in the protocol
design:
- allow only Sec values 3 and 5 and encode this as a single bit field
with multiple copies
- add a checksum character
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>