Commit graph

198 commits

Author SHA1 Message Date
Jouni Malinen
0aecf9e62c tests: Make sigma_dut AP SAE tests more robust
Wait some time before requesting disconnection to allow hostapd to
complete 4-way handshake processing. Wait some time after disconnection
has been completed on the STA before trying to use SAE again with the AP
so that hostapd has a chance to complete disconnection with UML
time-travel.

Signed-off-by: Jouni Malinen <j@w1.fi>
2023-12-09 19:02:38 +02:00
Jouni Malinen
004f618613 tests: Wait before initiating DPP from thread in sigma_dut testing
Starting a thread to initiate DPP before starting the responder through
sigma_dut can result in unexpected testing behavior since there may not
be enough time to get the responder enabled before timing out som
initiator actions. Wait a second at the beginning of the initiator
thread in dpp_init_conf() similarly to how this was handled in other
initiator-from-thread cases.

Signed-off-by: Jouni Malinen <j@w1.fi>
2023-11-04 12:41:02 +02:00
Jouni Malinen
cefd959566 tests: Terminate sigma_dut more forcefully if needed
Wait for stdout/stderr in a more robust manner to avoid blocking the
pipes and kill the sigma_dut process if it fails to terminate cleanly.

Signed-off-by: Jouni Malinen <j@w1.fi>
2023-11-04 12:31:23 +02:00
Jouni Malinen
ed4e845576 tests: Work around race condition for TRANSITION-DISABLE processing
This event may be sent before CTRL-EVENT-CONNECTED, so modify the test
cases to wait directly for TRANSITION-DISABLE by skipping the separate
wait for CTRL-EVENT-CONNECTED.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2023-11-02 15:57:39 +02:00
Jouni Malinen
4a28e0cb9c tests: Fix sigma_dut interaction with multiple status lines
It is possible for the sigma_dut process to be scheduled in a manner
that ends up combining the status,RUNNING and status,COMPLETE lines into
a single TCP message. This was supposed to be handled in the
sigma_dut_cmd() implementations, but that design had been broken by code
refactoring that changed the indentation level incorrectly.

Fixes: d68946d510 ("tests: sigma_dut and DPP push button first on Enrollee")
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2023-11-02 15:54:29 +02:00
Jouni Malinen
e5dfce38f7 RSN: Split EAPOL-Key group msg 1/2 processing more completely for WPA(v1)
Separate more of WPA(v1) functionality away from the RSN processing
code path.

Signed-off-by: Jouni Malinen <j@w1.fi>
2022-11-27 14:18:53 +02:00
Jouni Malinen
a3094ef80d tests: Allow more time for sigma_dut sta_reassoc commands
When these are issued while associated, scanning all channels can take a
significant amount of time. That happened to work for existing test
cases somewhat by accident since the scan was sometimes limited to only
the current operating channel. However, that is now changing and the
following two test cases started failing with the change, so make them
wait longer:
sigma_dut_sae_pw_id_ft sigma_dut_ft_rsnxe_used_mismatch

Signed-off-by: Jouni Malinen <j@w1.fi>
2022-11-05 13:43:06 +02:00
Jouni Malinen
97104a6588 tests: Clear sae_groups when SAE could be used
This makes sigma_dut_ap_dpp_qr* test cases with SAE more robust by
avoiding unexpected behavior. This was found with the following test
sequence:
mesh_sae_anti_clogging sigma_dut_ap_dpp_qr_sae

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-10-07 20:59:34 +03:00
Jouni Malinen
db46138de4 tests: sigma_dut DPP reconfiguration using SAE (Enrollee)
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-10-07 19:44:48 +03:00
Jouni Malinen
56321c0ac2 tests: Make sigma_dut_dpp_qr_mutual_resp_enrollee_connector_privacy more robust
Clear the dpp_connector_privacy_default parameter value that sigma_dut
set in wpa_supplicant at the end of the test case to avoid surprising
behavior for the following test cases. This was found with a failure in
the following test sequence:
sigma_dut_dpp_qr_mutual_resp_enrollee_connector_privacy
sigma_dut_dpp_proto_peer_disc_req

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-10-05 00:22:27 +03:00
Jouni Malinen
ca94fd70c8 tests: sigma_dut and DPP AP provisioning with SAE
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-10-03 19:20:21 +03:00
Jouni Malinen
a01266c925 tests: sigma_dut and EAP-AKA with imsiPrivacyCertID
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-09-14 20:31:55 +03:00
Jouni Malinen
05d3681f3e tests: Skip sigma_dut_dpp_tcp_configurator_init_mutual_unsupported_curve if needed
The part about checking the supported curves from the peer depends on
CONFIG_DPP3 and this test case needs to be skipped without that.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-08-26 17:27:45 +03:00
Jouni Malinen
d6e790e209 tests: DPP PB channel changes
Prepare for an implementation change for the PB discovery channel list.
Move the standlone (not an AP) PB Configurators to a preferred channel
and enable Configurator connectivity indication in APs that act as PB
Configurators.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-08-25 15:59:13 +03:00
Jouni Malinen
d68946d510 tests: sigma_dut and DPP push button first on Enrollee
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-08-23 18:56:17 +03:00
Jouni Malinen
b704dc72ef tests: sigma_dut and updated ConfResult value for Configurator failures
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-29 18:56:49 +03:00
Jouni Malinen
10104915af tests: sigma_dut and DPP PB session overlap
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-28 21:17:15 +03:00
Jouni Malinen
e7cbfa1c12 tests: sigma_dut and DPP Enrollee unsupported curves
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-28 11:22:44 +03:00
Jouni Malinen
ceae05cec2 tests: sigma_dut and DPP MUDURL setting for hostapd
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-27 13:43:58 +03:00
Jouni Malinen
b607d2723e tests: sigma_dut and DPP PB Configurator in wpa_supplicant
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-22 12:39:58 +03:00
Jouni Malinen
ca4e82cbfe tests: sigma_dut DPP/PKEX initiator as Configurator over TCP and Wi-Fi
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-21 20:32:32 +03:00
Jouni Malinen
dfa9183b11 tests: DPP reconfig after Controller-initiated operation through Relay
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-21 13:16:26 +03:00
Jouni Malinen
17216b5242 tests: sigma_dut DPP/PKEX initiator as Configurator (TCP) through Relay
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-19 23:28:33 +03:00
Jouni Malinen
0a4f391b1c tests: sigma_dut and DPP Connector Privacy
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-19 00:14:41 +03:00
Jouni Malinen
f2bb0839fb test: DPP 3rd party config information
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-16 17:22:23 +03:00
Jouni Malinen
248654d36b tests: sigma_dut DPP PB test cases
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-08 14:26:56 +03:00
Jouni Malinen
b9a222cdd7 tests: sigma_dut and DPP curve-from-URI special functionality
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-05-24 12:49:27 +03:00
Jouni Malinen
fa36e7ee48 tests: sigma_dut controlled STA and EAP-AKA parameters
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-05-24 00:44:03 +03:00
Jouni Malinen
e90ea900a9 tests: sigma_dut DPP TCP Configurator as initiator with addr from URI
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-05-19 22:54:44 +03:00
Jouni Malinen
387b341ead tests: Fix SAE-PK capability checks for sigma_dut test cases
These were testing only of SAE, not SAE-PK capability, and needs to be
skipped in SAE-PK is not included in the build.

Signed-off-by: Jouni Malinen <j@w1.fi>
2022-04-18 11:20:33 +03:00
Jouni Malinen
ae301fd37a tests: Skip sigma_dut_suite_b_rsa DHE case with BoringSSL
BoringSSL is known not to support this option, so skip it to allow rest
of the test case to be performed without known failures.

Signed-off-by: Jouni Malinen <j@w1.fi>
2022-04-15 13:43:30 +03:00
Jouni Malinen
364022ddef tests: sigma_dut DPP URI curves list override
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-04-14 17:06:02 +03:00
Jouni Malinen
7c8fcd6baf tests: Fix sigma_dut_cmd() processing for the return value
The first sock.recv() may return both the status,RUNNING and the
following status line if the sigma_dut process ends up being faster in
writing the result than the test script is in reading the result. This
resulted in unexpected behavior and odd error messages when parsing the
result in the test cases. Fix this by dropping the status,RUNNING line
from the result in case the buffer includes multiple lines.

Signed-off-by: Jouni Malinen <j@w1.fi>
2022-03-12 19:00:36 +02:00
Jouni Malinen
0c51cf624c tests: sigma_dut DPP Configurator (MUD URL, NAK change)
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-03-10 18:29:34 +02:00
Jouni Malinen
800ae647df tests: Check DPP3 support in the build for netAccessKey curve changes
These test cases need to be skipped if CONFIG_DPP3=y is not defined in
the build.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-03-09 21:26:28 +02:00
Jouni Malinen
77ae98511d tests: sigma_dut and DPP netAccessKey curve change
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-03-09 01:20:49 +02:00
Jouni Malinen
1d4cd24d0b tests: sigma_dut and DPP Reconfig Auth Req error cases
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-03-08 00:06:00 +02:00
Jouni Malinen
fc78c13550 tests: sigma_dut and DPP PKEXv1 responder
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-03-07 21:38:25 +02:00
Jouni Malinen
010e7dddce tests: Clear sae_groups in sigma_dut_ap_ft_rsnxe_used_mismatch
This is needed to avoid test failures when a previous test case might
have restricted the set of allowed SAE groups.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-02-24 00:23:25 +02:00
Jouni Malinen
c4dc90c1c0 tests: Remove ignore_old_scan_res clearing from the test scripts
Now that wpa_supplicant does this internally as a part of the FLUSH
command, there is no need for the test scripts to try to clear the
parameter between test cases.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-02-04 21:29:52 +02:00
Jouni Malinen
a8c43b1822 tests: Use check_sae_capab() where possible
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-02-01 18:16:35 +02:00
Jouni Malinen
4feb46ddb4 tests: Fix CONFIG_DPP3=y dependency in couple of test cases
These could not pass without DPP3 support.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-01-31 18:16:29 +02:00
Jouni Malinen
75f42be0a7 tests: sigma_dut and DPP PKEX over TCP
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-01-27 20:50:39 +02:00
Jouni Malinen
75d791c0e3 tests: sigma_dut and additional protocol tests for DPP Network Intro
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-01-27 18:44:57 +02:00
Jouni Malinen
c93679a87f tests: sigma_dut forcing PKEX v1 only
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-01-26 00:40:09 +02:00
Jouni Malinen
93a19abcaf tests: sigma_dut DPP/PKEXv2 initiator and fallback to v1
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-01-24 22:58:38 +02:00
Jouni Malinen
9a9b461fee tests: Check SAE capability for couple of forgotten sigma_dut cases
Signed-off-by: Jouni Malinen <j@w1.fi>
2021-03-14 13:08:04 +02:00
Jouni Malinen
8ea3561c6c tests: Fix sigma_dut_ap_dpp_tcp_enrollee_init to stop hostapd
This test case was missing an explicit CAPI ap_reset_default and that
could result in hostapd being left running at the end of the test case.
This could result in issues with following test cases if they used a new
radio interface from HWSimRadio().

Signed-off-by: Jouni Malinen <j@w1.fi>
2021-02-27 21:07:54 +02:00
Jouni Malinen
39fac5abd1 tests: Fix clean at the end of sigma_dut_client_privacy
These commands were being issues to incorrect wpa_supplicant instance
and were missing clearing of the MAC_RAND_SCAN parameter.

Signed-off-by: Jouni Malinen <j@w1.fi>
2021-02-21 17:21:48 +02:00
Jouni Malinen
9acf8da223 tests: Use a longer timeout for connection in sigma_dut DPP test cases
It was possible for these test cases to fail if the first scan iteration
did not find the AP since the 10 second timeout was small enough to
terminate the second attempt before fetching the scan results. Increase
this timeout to allow at least two full scan iterations to be completed
before declaring failure.

Signed-off-by: Jouni Malinen <j@w1.fi>
2021-02-20 16:10:47 +02:00