One of the sigma_dut testing cases missed the t.join() call to make
surte the separate thread terminated. This could result in confusing
"unexpected stdout output" in a middle of an unrelated test case.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Wait some time between the first DPP Authentication Response that
indicates the response is not yet available and the second DPP
Authentication Response to make this sequence a bit more realistic and
less likely to hit race conditions with UML time-travel.
Signed-off-by: Jouni Malinen <j@w1.fi>
DPP initiator will try three channels in this sequence and it can take
very close to the previously used five second timeout before being able
to try on the actual operating channel of the AP. This could result in
the test case failing unnecessarily. Increase the timeout to avoid this.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Wait for AP/GO to complete processing before taking the next step in a
test instead of waiting just for STA. This avoids race conditions with
UML time-travel.
Signed-off-by: Jouni Malinen <j@w1.fi>
Wait some time before requesting disconnection to allow hostapd to
complete 4-way handshake processing. Wait some time after disconnection
has been completed on the STA before trying to use SAE again with the AP
so that hostapd has a chance to complete disconnection with UML
time-travel.
Signed-off-by: Jouni Malinen <j@w1.fi>
Starting a thread to initiate DPP before starting the responder through
sigma_dut can result in unexpected testing behavior since there may not
be enough time to get the responder enabled before timing out som
initiator actions. Wait a second at the beginning of the initiator
thread in dpp_init_conf() similarly to how this was handled in other
initiator-from-thread cases.
Signed-off-by: Jouni Malinen <j@w1.fi>
Wait for stdout/stderr in a more robust manner to avoid blocking the
pipes and kill the sigma_dut process if it fails to terminate cleanly.
Signed-off-by: Jouni Malinen <j@w1.fi>
This event may be sent before CTRL-EVENT-CONNECTED, so modify the test
cases to wait directly for TRANSITION-DISABLE by skipping the separate
wait for CTRL-EVENT-CONNECTED.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
It is possible for the sigma_dut process to be scheduled in a manner
that ends up combining the status,RUNNING and status,COMPLETE lines into
a single TCP message. This was supposed to be handled in the
sigma_dut_cmd() implementations, but that design had been broken by code
refactoring that changed the indentation level incorrectly.
Fixes: d68946d510 ("tests: sigma_dut and DPP push button first on Enrollee")
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
When these are issued while associated, scanning all channels can take a
significant amount of time. That happened to work for existing test
cases somewhat by accident since the scan was sometimes limited to only
the current operating channel. However, that is now changing and the
following two test cases started failing with the change, so make them
wait longer:
sigma_dut_sae_pw_id_ft sigma_dut_ft_rsnxe_used_mismatch
Signed-off-by: Jouni Malinen <j@w1.fi>
This makes sigma_dut_ap_dpp_qr* test cases with SAE more robust by
avoiding unexpected behavior. This was found with the following test
sequence:
mesh_sae_anti_clogging sigma_dut_ap_dpp_qr_sae
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Clear the dpp_connector_privacy_default parameter value that sigma_dut
set in wpa_supplicant at the end of the test case to avoid surprising
behavior for the following test cases. This was found with a failure in
the following test sequence:
sigma_dut_dpp_qr_mutual_resp_enrollee_connector_privacy
sigma_dut_dpp_proto_peer_disc_req
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
The part about checking the supported curves from the peer depends on
CONFIG_DPP3 and this test case needs to be skipped without that.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Prepare for an implementation change for the PB discovery channel list.
Move the standlone (not an AP) PB Configurators to a preferred channel
and enable Configurator connectivity indication in APs that act as PB
Configurators.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
These were testing only of SAE, not SAE-PK capability, and needs to be
skipped in SAE-PK is not included in the build.
Signed-off-by: Jouni Malinen <j@w1.fi>
BoringSSL is known not to support this option, so skip it to allow rest
of the test case to be performed without known failures.
Signed-off-by: Jouni Malinen <j@w1.fi>
The first sock.recv() may return both the status,RUNNING and the
following status line if the sigma_dut process ends up being faster in
writing the result than the test script is in reading the result. This
resulted in unexpected behavior and odd error messages when parsing the
result in the test cases. Fix this by dropping the status,RUNNING line
from the result in case the buffer includes multiple lines.
Signed-off-by: Jouni Malinen <j@w1.fi>
This is needed to avoid test failures when a previous test case might
have restricted the set of allowed SAE groups.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Now that wpa_supplicant does this internally as a part of the FLUSH
command, there is no need for the test scripts to try to clear the
parameter between test cases.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>