Since the kernel actually passes the command-line parameters
as environment variables to the init script, there's no need
to parse them out of /proc/cmdline.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
It can be useful to configure a different module directory, so you don't
need to install the kernel modules in the host /lib/modules/ location.
Allow configuring it in the config file.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
If cfg80211 is built into the kernel, then it may/will have
loaded the regdb before we mount our own /lib/firmware. This
may result in using the wrong regulatory data. Fix this by
using iw to reload the regdb after mounting it.
Fixes: a29c2399a7 ("tests: Add regulatory database to VMs")
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
The part about checking the supported curves from the peer depends on
CONFIG_DPP3 and this test case needs to be skipped without that.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Prepare for an implementation change for the PB discovery channel list.
Move the standlone (not an AP) PB Configurators to a preferred channel
and enable Configurator connectivity indication in APs that act as PB
Configurators.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Configurator station seems to be unable to get the first Authentication
Request frame transmitted through mac80211_hwsim for some reason. It is
not really clear why this happens and why it started happening now, but
as a temporary workaround, wait a second here since that seems to avoid
this for some unknown reason.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This test case assumed that the p2p_pref_chan 128:44 parameter would
have resulted in channel 44 (5220 MHz) being selected. That does not
work anymore since that channel was marked to require DFS/radar
detection in regdb. Fix the text case by changing to use another country
with rules that match the test case expectations.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
It looks like some test cases could fail due to timeouts since the 10
second wait may not be sufficient to cover some cases where 6 GHz
channels get scanned. Increase the timeouts to avoid hitting such cases.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
It looks like the host update of regulatory information can still get
through somehow, so add alternative expected values for the supported
operating classes for cases where 6 GHz frequencies were added recently.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This is in preparation to allow the implementation in hostapd to be
changed to accept removal of PKEX information without indicating an
error after it have been automatically removed at the successful
completion of PKEX.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This started failing with the OCV implementation change to ignore the
second segment when using a 160 MHz channel.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Try to avoid an exception while processing an exception that indicates
the test case failed. Explicit DISCONNECT command here can avoid the
undesired FAIL-BUSY from cleanup SCAN.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
This can be used to make sure wpa_supplicant does not process DPP
messages sent in Public Action frames when a test setup is targeting
DPP-over-TCP.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Use imsi_privacy_cert as the name of the configuration parameter for the
X.509v3 certificate that contains the RSA public key needed for IMSI
privacy. The only allowed format for this information is a PEM-encoded
X.509 certificate, so the previous name was somewhat confusing.
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
Unfortunately, some objects (WlantestCapture, WpaSupplicant
and wpaspy.Ctrl) use __del__ and actually have some logic
there. This is more or less wrong, and we should be using
context managers for it. However, cleaning that up is a
pretty large task.
Unfortunately, __del__ can cause reentrant logging which is
wrong too, because it might be invoked while in the middle
of a logging call, and the __del__ of these objects closes
connections and logs while doing that.
Since we're (likely) using cpython, we can work around this
by explicitly calling gc.collect() in a context where the
logging and close is fine, not only ensuring that all the
connections are closed properly before the next test, but
also fixing the issue with reentrant logging.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Instead of printing a very long line of the failed tests, print the test
case names on separate lines up to the number of available lines at the
bottom of the screen. This avoids some issues with curses and overlong
lines. Furthermore, display the last failed test cases instead of
somewhat confusing sequence of test case names from the VMs.
Signed-off-by: Jouni Malinen <j@w1.fi>