Fix 20/40 MHz co-ex report processing with obss_interval=0
If OBSS scan interval is not set, the AP must not schedule a timeout to restore 40 MHz operation immediately after having moved to a 20 MHz channel based on an unsolicited co-ex report. Fix this by scheduling the timeout only if obss_interval is non-zero. Since we do not currently support AP doing OBSS scans after the initial BSS setup, this means practically that 40-to-20 MHz transition is allowed, but 20-to-40 MHz is not with obss_interval=0. The latter gets enabled if obss_interval is set to a non-zero value so that associated STAs can take care of OBSS scanning. Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
This commit is contained in:
parent
5095a6b6fc
commit
d027c7b118
1 changed files with 2 additions and 1 deletions
|
@ -292,7 +292,8 @@ void hostapd_2040_coex_action(struct hostapd_data *hapd,
|
|||
iface->conf->secondary_channel = 0;
|
||||
ieee802_11_set_beacons(iface);
|
||||
}
|
||||
if (!iface->num_sta_ht40_intolerant) {
|
||||
if (!iface->num_sta_ht40_intolerant &&
|
||||
iface->conf->obss_interval) {
|
||||
unsigned int delay_time;
|
||||
delay_time = OVERLAPPING_BSS_TRANS_DELAY_FACTOR *
|
||||
iface->conf->obss_interval;
|
||||
|
|