D-Bus: Demote timeout/flush messages to MSG_MSGDUMP
We intentionally don't emit property-changed signals on every property update -- for "less timing critical" messages we delay up to 5 milliseconds waiting to see if we can batch them together. When the timer hits, we emit the signal anyway and (potentially) log this message. This amounts to effectively tracing every property update, which can be quite excessive. Lower this to MSGDUMP, so MSG_DEBUG can remain slightly more sane. Signed-off-by: Brian Norris <briannorris@chromium.org>
This commit is contained in:
parent
9cff5c320c
commit
cc2fd94258
1 changed files with 1 additions and 1 deletions
|
@ -742,7 +742,7 @@ static void flush_object_timeout_handler(void *eloop_ctx, void *timeout_ctx)
|
|||
DBusConnection *con = eloop_ctx;
|
||||
struct wpa_dbus_object_desc *obj_desc = timeout_ctx;
|
||||
|
||||
wpa_printf(MSG_DEBUG,
|
||||
wpa_printf(MSG_MSGDUMP,
|
||||
"dbus: %s: Timeout - sending changed properties of object %s",
|
||||
__func__, obj_desc->path);
|
||||
wpa_dbus_flush_object_changed_properties(con, obj_desc->path);
|
||||
|
|
Loading…