tests: Double the connection timeout for EAP cases
It looks like slow virtual machines may have issues to complete some EAP authentication cases (e.g., EAP-EKE in ap_ft_eap) within the 10 second timeout under load. Double the timeout to avoid incorrect test failures. Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
This commit is contained in:
parent
c57c1ed6b3
commit
7559ad7af6
1 changed files with 6 additions and 3 deletions
|
@ -220,10 +220,10 @@ class WpaSupplicant:
|
|||
raise Exception("SELECT_NETWORK failed")
|
||||
return None
|
||||
|
||||
def connect_network(self, id):
|
||||
def connect_network(self, id, timeout=10):
|
||||
self.dump_monitor()
|
||||
self.select_network(id)
|
||||
ev = self.wait_event(["CTRL-EVENT-CONNECTED"], timeout=10)
|
||||
ev = self.wait_event(["CTRL-EVENT-CONNECTED"], timeout=timeout)
|
||||
if ev is None:
|
||||
raise Exception("Association with the AP timed out")
|
||||
self.dump_monitor()
|
||||
|
@ -663,7 +663,10 @@ class WpaSupplicant:
|
|||
if only_add_network:
|
||||
return id
|
||||
if wait_connect:
|
||||
self.connect_network(id)
|
||||
if eap:
|
||||
self.connect_network(id, timeout=20)
|
||||
else:
|
||||
self.connect_network(id)
|
||||
else:
|
||||
self.dump_monitor()
|
||||
self.select_network(id)
|
||||
|
|
Loading…
Reference in a new issue