netbox-agent/tests/fixtures/dmidecode/Dell_DSS7500
2020-02-02 20:24:01 +01:00

868 lines
21 KiB
Text

# dmidecode 2.12
SMBIOS 2.8 present.
57 structures occupying 3093 bytes.
Table at 0x7AF09000.
Handle 0xDA00, DMI type 218, 11 bytes
OEM-specific Type
Header and Data:
DA 0B 00 DA B2 00 17 20 0E 10 03
Handle 0x0000, DMI type 0, 24 bytes
BIOS Information
Vendor: Dell Inc.
Version: 2.3.4
Release Date: 11/10/2016
Address: 0xF0000
Runtime Size: 64 kB
ROM Size: 16384 kB
Characteristics:
ISA is supported
PCI is supported
PNP is supported
BIOS is upgradeable
BIOS shadowing is allowed
Boot from CD is supported
Selectable boot is supported
EDD is supported
Japanese floppy for Toshiba 1.2 MB is supported (int 13h)
5.25"/360 kB floppy services are supported (int 13h)
5.25"/1.2 MB floppy services are supported (int 13h)
3.5"/720 kB floppy services are supported (int 13h)
8042 keyboard services are supported (int 9h)
Serial services are supported (int 14h)
CGA/mono video services are supported (int 10h)
ACPI is supported
USB legacy is supported
BIOS boot specification is supported
Function key-initiated network boot is supported
Targeted content distribution is supported
UEFI is supported
BIOS Revision: 2.3
Handle 0x0100, DMI type 1, 27 bytes
System Information
Manufacturer: Dell Inc.
Product Name: DSS7500
Version: Not Specified
Serial Number: 4242-SERVICE_TAG
UUID: 4C4C4544-0048-5110-804A-C6C04F594A32
Wake-up Type: Power Switch
SKU Number: SKU=NotProvided;ModelName=DSS7500
Family: Not Specified
Handle 0x0200, DMI type 2, 8 bytes
Base Board Information
Manufacturer: Dell Inc.
Product Name: 0X89R8
Version: A04
Serial Number: 4242
Handle 0x0300, DMI type 3, 22 bytes
Chassis Information
Manufacturer: Dell Inc.
Type: Rack Mount Chassis
Lock: Present
Version: Not Specified
Serial Number: 4242
Asset Tag: Not Specified
Boot-up State: Safe
Power Supply State: Safe
Thermal State: Safe
Security Status: Unknown
OEM Information: 0x00000000
Height: 4 U
Number Of Power Cords: Unspecified
Contained Elements: 0
SKU Number: Not Specified
Handle 0x0400, DMI type 4, 42 bytes
Processor Information
Socket Designation: CPU1
Type: Central Processor
Family: Xeon
Manufacturer: Intel
ID: F1 06 04 00 FF FB EB BF
Signature: Type 0, Family 6, Model 79, Stepping 1
Flags:
FPU (Floating-point unit on-chip)
VME (Virtual mode extension)
DE (Debugging extension)
PSE (Page size extension)
TSC (Time stamp counter)
MSR (Model specific registers)
PAE (Physical address extension)
MCE (Machine check exception)
CX8 (CMPXCHG8 instruction supported)
APIC (On-chip APIC hardware supported)
SEP (Fast system call)
MTRR (Memory type range registers)
PGE (Page global enable)
MCA (Machine check architecture)
CMOV (Conditional move instruction supported)
PAT (Page attribute table)
PSE-36 (36-bit page size extension)
CLFSH (CLFLUSH instruction supported)
DS (Debug store)
ACPI (ACPI supported)
MMX (MMX technology supported)
FXSR (FXSAVE and FXSTOR instructions supported)
SSE (Streaming SIMD extensions)
SSE2 (Streaming SIMD extensions 2)
SS (Self-snoop)
HTT (Multi-threading)
TM (Thermal monitor supported)
PBE (Pending break enabled)
Version: Intel(R) Xeon(R) CPU E5-2630 v4 @ 2.20GHz
Voltage: 1.3 V
External Clock: 8000 MHz
Max Speed: 4000 MHz
Current Speed: 2200 MHz
Status: Populated, Enabled
Upgrade: <OUT OF SPEC>
L1 Cache Handle: 0x0700
L2 Cache Handle: 0x0701
L3 Cache Handle: 0x0702
Serial Number: 4242
Asset Tag: Not Specified
Part Number: Not Specified
Core Count: 10
Core Enabled: 10
Thread Count: 10
Characteristics:
64-bit capable
Multi-Core
Hardware Thread
Execute Protection
Enhanced Virtualization
Power/Performance Control
Handle 0x0401, DMI type 4, 42 bytes
Processor Information
Socket Designation: CPU2
Type: Central Processor
Family: Xeon
Manufacturer: Intel
ID: F1 06 04 00 FF FB EB BF
Signature: Type 0, Family 6, Model 79, Stepping 1
Flags:
FPU (Floating-point unit on-chip)
VME (Virtual mode extension)
DE (Debugging extension)
PSE (Page size extension)
TSC (Time stamp counter)
MSR (Model specific registers)
PAE (Physical address extension)
MCE (Machine check exception)
CX8 (CMPXCHG8 instruction supported)
APIC (On-chip APIC hardware supported)
SEP (Fast system call)
MTRR (Memory type range registers)
PGE (Page global enable)
MCA (Machine check architecture)
CMOV (Conditional move instruction supported)
PAT (Page attribute table)
PSE-36 (36-bit page size extension)
CLFSH (CLFLUSH instruction supported)
DS (Debug store)
ACPI (ACPI supported)
MMX (MMX technology supported)
FXSR (FXSAVE and FXSTOR instructions supported)
SSE (Streaming SIMD extensions)
SSE2 (Streaming SIMD extensions 2)
SS (Self-snoop)
HTT (Multi-threading)
TM (Thermal monitor supported)
PBE (Pending break enabled)
Version: Intel(R) Xeon(R) CPU E5-2630 v4 @ 2.20GHz
Voltage: 1.3 V
External Clock: 8000 MHz
Max Speed: 4000 MHz
Current Speed: 2200 MHz
Status: Populated, Enabled
Upgrade: <OUT OF SPEC>
L1 Cache Handle: 0x0703
L2 Cache Handle: 0x0704
L3 Cache Handle: 0x0705
Serial Number: 4242
Asset Tag: Not Specified
Part Number: Not Specified
Core Count: 10
Core Enabled: 10
Thread Count: 10
Characteristics:
64-bit capable
Multi-Core
Hardware Thread
Execute Protection
Enhanced Virtualization
Power/Performance Control
Handle 0x0700, DMI type 7, 19 bytes
Cache Information
Socket Designation: Not Specified
Configuration: Enabled, Not Socketed, Level 1
Operational Mode: Write Back
Location: Internal
Installed Size: 640 kB
Maximum Size: 640 kB
Supported SRAM Types:
Unknown
Installed SRAM Type: Unknown
Speed: Unknown
Error Correction Type: Parity
System Type: Unified
Associativity: 8-way Set-associative
Handle 0x0701, DMI type 7, 19 bytes
Cache Information
Socket Designation: Not Specified
Configuration: Enabled, Not Socketed, Level 2
Operational Mode: Write Back
Location: Internal
Installed Size: 2560 kB
Maximum Size: 2560 kB
Supported SRAM Types:
Unknown
Installed SRAM Type: Unknown
Speed: Unknown
Error Correction Type: Single-bit ECC
System Type: Unified
Associativity: 8-way Set-associative
Handle 0x0702, DMI type 7, 19 bytes
Cache Information
Socket Designation: Not Specified
Configuration: Enabled, Not Socketed, Level 3
Operational Mode: Write Back
Location: Internal
Installed Size: 25600 kB
Maximum Size: 25600 kB
Supported SRAM Types:
Unknown
Installed SRAM Type: Unknown
Speed: Unknown
Error Correction Type: Single-bit ECC
System Type: Unified
Associativity: 20-way Set-associative
Handle 0x0703, DMI type 7, 19 bytes
Cache Information
Socket Designation: Not Specified
Configuration: Enabled, Not Socketed, Level 1
Operational Mode: Write Back
Location: Internal
Installed Size: 640 kB
Maximum Size: 640 kB
Supported SRAM Types:
Unknown
Installed SRAM Type: Unknown
Speed: Unknown
Error Correction Type: Parity
System Type: Unified
Associativity: 8-way Set-associative
Handle 0x0704, DMI type 7, 19 bytes
Cache Information
Socket Designation: Not Specified
Configuration: Enabled, Not Socketed, Level 2
Operational Mode: Write Back
Location: Internal
Installed Size: 2560 kB
Maximum Size: 2560 kB
Supported SRAM Types:
Unknown
Installed SRAM Type: Unknown
Speed: Unknown
Error Correction Type: Single-bit ECC
System Type: Unified
Associativity: 8-way Set-associative
Handle 0x0705, DMI type 7, 19 bytes
Cache Information
Socket Designation: Not Specified
Configuration: Enabled, Not Socketed, Level 3
Operational Mode: Write Back
Location: Internal
Installed Size: 25600 kB
Maximum Size: 25600 kB
Supported SRAM Types:
Unknown
Installed SRAM Type: Unknown
Speed: Unknown
Error Correction Type: Single-bit ECC
System Type: Unified
Associativity: 20-way Set-associative
Handle 0x0800, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: Not Specified
Internal Connector Type: None
External Reference Designator: Back USB port 2
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0801, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: Internal USB port 1
Internal Connector Type: Access Bus (USB)
External Reference Designator: Not Specified
External Connector Type: None
Port Type: USB
Handle 0x0802, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: Not Specified
Internal Connector Type: None
External Reference Designator: Front USB port 2
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0803, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: Not Specified
Internal Connector Type: None
External Reference Designator: Back USB port 1
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0804, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: Not Specified
Internal Connector Type: None
External Reference Designator: Front USB port 1
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x0805, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: Not Specified
Internal Connector Type: None
External Reference Designator: Video port 1
External Connector Type: DB-15 female
Port Type: Video Port
Handle 0x0806, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: Not Specified
Internal Connector Type: None
External Reference Designator: Serial port 1
External Connector Type: DB-9 male
Port Type: Serial Port 16550A Compatible
Handle 0x0900, DMI type 9, 17 bytes
System Slot Information
Designation: PCIe Slot 1
Type: x8 PCI Express 3
Current Usage: Available
Length: Long
Characteristics:
3.3 V is provided
PME signal is supported
Handle 0x0901, DMI type 9, 17 bytes
System Slot Information
Designation: PCIe Slot 2
Type: x8 PCI Express 3 x16
Current Usage: In Use
Length: Long
Characteristics:
3.3 V is provided
PME signal is supported
Bus Address: 0000:04:00.0
Handle 0x0902, DMI type 9, 17 bytes
System Slot Information
Designation: PCIe Slot 3
Type: x8 PCI Express 3
Current Usage: Available
Length: Long
Characteristics:
3.3 V is provided
PME signal is supported
Handle 0x0903, DMI type 9, 17 bytes
System Slot Information
Designation: PCIe Slot 4
Type: x8 PCI Express 3
Current Usage: In Use
Length: Long
Characteristics:
3.3 V is provided
PME signal is supported
Bus Address: 0000:06:00.0
Handle 0x0B00, DMI type 11, 5 bytes
OEM Strings
String 1: Dell System
String 2: 5[0000]
String 3: 1[06B6]
String 4: 7[0721]
String 5: 8[Dell Inc.]
String 6: 9[DSS7500]
String 7: 10[2.3.4]
String 8: 11[01.00.00]
String 9: 12[www.dell.com]
String 10: 14[1]
String 11: 17[8F27911A0C407F63]
String 12: 17[8F28041BFDD8E7E6]
String 13: 18[0]
String 14: 19[1]
String 15: 19[1]
Handle 0x0C00, DMI type 12, 5 bytes
System Configuration Options
Option 1: NVRAM_CLR: Clear user settable NVRAM areas and set defaults
Option 2: PWRD_EN: Close to enable password
Handle 0x0D00, DMI type 13, 22 bytes
BIOS Language Information
Language Description Format: Long
Installable Languages: 1
en|US|iso8859-1
Currently Installed Language: en|US|iso8859-1
Handle 0x1000, DMI type 16, 23 bytes
Physical Memory Array
Location: System Board Or Motherboard
Use: System Memory
Error Correction Type: Multi-bit ECC
Maximum Capacity: 1536 GB
Error Information Handle: Not Provided
Number Of Devices: 12
Handle 0x1100, DMI type 17, 40 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 16384 MB
Form Factor: DIMM
Set: 1
Locator: A1
Bank Locator: Not Specified
Type: <OUT OF SPEC>
Type Detail: Synchronous Registered (Buffered)
Speed: 2400 MHz
Manufacturer: 002C00B3002C
Serial Number: 4242
Asset Tag: 00171230
Part Number: 18ASF2G72PDZ-2G3B1
Rank: 2
Configured Clock Speed: 2133 MHz
Minimum voltage: 1.200 V
Maximum voltage: 1.200 V
Configured voltage: 1.200 V
Handle 0x1101, DMI type 17, 40 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 16384 MB
Form Factor: DIMM
Set: 1
Locator: A2
Bank Locator: Not Specified
Type: <OUT OF SPEC>
Type Detail: Synchronous Registered (Buffered)
Speed: 2400 MHz
Manufacturer: 002C00B3002C
Serial Number: 4242
Asset Tag: 00171230
Part Number: 18ASF2G72PDZ-2G3B1
Rank: 2
Configured Clock Speed: 2133 MHz
Minimum voltage: 1.200 V
Maximum voltage: 1.200 V
Configured voltage: 1.200 V
Handle 0x1102, DMI type 17, 40 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 16384 MB
Form Factor: DIMM
Set: 1
Locator: A3
Bank Locator: Not Specified
Type: <OUT OF SPEC>
Type Detail: Synchronous Registered (Buffered)
Speed: 2400 MHz
Manufacturer: 002C00B3002C
Serial Number: 4242
Asset Tag: 00171230
Part Number: 18ASF2G72PDZ-2G3B1
Rank: 2
Configured Clock Speed: 2133 MHz
Minimum voltage: 1.200 V
Maximum voltage: 1.200 V
Configured voltage: 1.200 V
Handle 0x1103, DMI type 17, 40 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 16384 MB
Form Factor: DIMM
Set: 1
Locator: A4
Bank Locator: Not Specified
Type: <OUT OF SPEC>
Type Detail: Synchronous Registered (Buffered)
Speed: 2400 MHz
Manufacturer: 002C00B3002C
Serial Number: 4242
Asset Tag: 00171230
Part Number: 18ASF2G72PDZ-2G3B1
Rank: 2
Configured Clock Speed: 2133 MHz
Minimum voltage: 1.200 V
Maximum voltage: 1.200 V
Configured voltage: 1.200 V
Handle 0x1104, DMI type 17, 40 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 16384 MB
Form Factor: DIMM
Set: 2
Locator: A5
Bank Locator: Not Specified
Type: <OUT OF SPEC>
Type Detail: Synchronous Registered (Buffered)
Speed: 2400 MHz
Manufacturer: 002C00B3002C
Serial Number: 4242
Asset Tag: 00171230
Part Number: 18ASF2G72PDZ-2G3B1
Rank: 2
Configured Clock Speed: 2133 MHz
Minimum voltage: 1.200 V
Maximum voltage: 1.200 V
Configured voltage: 1.200 V
Handle 0x1105, DMI type 17, 40 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 16384 MB
Form Factor: DIMM
Set: 2
Locator: A6
Bank Locator: Not Specified
Type: <OUT OF SPEC>
Type Detail: Synchronous Registered (Buffered)
Speed: 2400 MHz
Manufacturer: 002C00B3002C
Serial Number: 4242
Asset Tag: 00171230
Part Number: 18ASF2G72PDZ-2G3B1
Rank: 2
Configured Clock Speed: 2133 MHz
Minimum voltage: 1.200 V
Maximum voltage: 1.200 V
Configured voltage: 1.200 V
Handle 0x1106, DMI type 17, 40 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 16384 MB
Form Factor: DIMM
Set: 2
Locator: A7
Bank Locator: Not Specified
Type: <OUT OF SPEC>
Type Detail: Synchronous Registered (Buffered)
Speed: 2400 MHz
Manufacturer: 002C00B3002C
Serial Number: 4242
Asset Tag: 00171230
Part Number: 18ASF2G72PDZ-2G3B1
Rank: 2
Configured Clock Speed: 2133 MHz
Minimum voltage: 1.200 V
Maximum voltage: 1.200 V
Configured voltage: 1.200 V
Handle 0x1107, DMI type 17, 40 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 16384 MB
Form Factor: DIMM
Set: 2
Locator: A8
Bank Locator: Not Specified
Type: <OUT OF SPEC>
Type Detail: Synchronous Registered (Buffered)
Speed: 2400 MHz
Manufacturer: 002C00B3002C
Serial Number: 4242
Asset Tag: 00171230
Part Number: 18ASF2G72PDZ-2G3B1
Rank: 2
Configured Clock Speed: 2133 MHz
Minimum voltage: 1.200 V
Maximum voltage: 1.200 V
Configured voltage: 1.200 V
Handle 0x1108, DMI type 17, 40 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 16384 MB
Form Factor: DIMM
Set: 3
Locator: B1
Bank Locator: Not Specified
Type: <OUT OF SPEC>
Type Detail: Synchronous Registered (Buffered)
Speed: 2400 MHz
Manufacturer: 002C00B3002C
Serial Number: 4242
Asset Tag: 00171230
Part Number: 18ASF2G72PDZ-2G3B1
Rank: 2
Configured Clock Speed: 2133 MHz
Minimum voltage: 1.200 V
Maximum voltage: 1.200 V
Configured voltage: 1.200 V
Handle 0x1109, DMI type 17, 40 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 16384 MB
Form Factor: DIMM
Set: 3
Locator: B2
Bank Locator: Not Specified
Type: <OUT OF SPEC>
Type Detail: Synchronous Registered (Buffered)
Speed: 2400 MHz
Manufacturer: 002C00B3002C
Serial Number: 4242
Asset Tag: 00171230
Part Number: 18ASF2G72PDZ-2G3B1
Rank: 2
Configured Clock Speed: 2133 MHz
Minimum voltage: 1.200 V
Maximum voltage: 1.200 V
Configured voltage: 1.200 V
Handle 0x110A, DMI type 17, 40 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 16384 MB
Form Factor: DIMM
Set: 3
Locator: B3
Bank Locator: Not Specified
Type: <OUT OF SPEC>
Type Detail: Synchronous Registered (Buffered)
Speed: 2400 MHz
Manufacturer: 002C00B3002C
Serial Number: 4242
Asset Tag: 00171230
Part Number: 18ASF2G72PDZ-2G3B1
Rank: 2
Configured Clock Speed: 2133 MHz
Minimum voltage: 1.200 V
Maximum voltage: 1.200 V
Configured voltage: 1.200 V
Handle 0x110B, DMI type 17, 40 bytes
Memory Device
Array Handle: 0x1000
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 16384 MB
Form Factor: DIMM
Set: 3
Locator: B4
Bank Locator: Not Specified
Type: <OUT OF SPEC>
Type Detail: Synchronous Registered (Buffered)
Speed: 2400 MHz
Manufacturer: 002C00B3002C
Serial Number: 4242
Asset Tag: 00171230
Part Number: 18ASF2G72PDZ-2G3B1
Rank: 2
Configured Clock Speed: 2133 MHz
Minimum voltage: 1.200 V
Maximum voltage: 1.200 V
Configured voltage: 1.200 V
Handle 0x1300, DMI type 19, 31 bytes
Memory Array Mapped Address
Starting Address: 0x00000000000
Ending Address: 0x0007FFFFFFF
Range Size: 2 GB
Physical Array Handle: 0x1000
Partition Width: 2
Handle 0x1301, DMI type 19, 31 bytes
Memory Array Mapped Address
Starting Address: 0x00100000000
Ending Address: 0x0307FFFFFFF
Range Size: 190 GB
Physical Array Handle: 0x1000
Partition Width: 2
Handle 0x2000, DMI type 32, 11 bytes
System Boot Information
Status: No errors detected
Handle 0x2600, DMI type 38, 18 bytes
IPMI Device Information
Interface Type: KCS (Keyboard Control Style)
Specification Version: 2.0
I2C Slave Address: 0x10
NV Storage Device: Not Present
Base Address: 0x0000000000000CA8 (I/O)
Register Spacing: 32-bit Boundaries
Interrupt Polarity: Active High
Interrupt Trigger Mode: Edge
Interrupt Number: a
Handle 0x2700, DMI type 39, 22 bytes
System Power Supply
Location: Not Specified
Name: PWR SPLY,1600W,RDNT,DELTA
Manufacturer: DELL
Serial Number: 4242
Asset Tag: Not Specified
Model Part Number: 0685W7A00
Revision: Not Specified
Max Power Capacity: 1600 W
Status: Present, Unknown
Type: Unknown
Input Voltage Range Switching: Unknown
Plugged: Yes
Hot Replaceable: Yes
Handle 0x2701, DMI type 39, 22 bytes
System Power Supply
Location: Not Specified
Name: PWR SPLY,1600W,RDNT,DELTA
Manufacturer: DELL
Serial Number: 4242
Asset Tag: Not Specified
Model Part Number: 0685W7A00
Revision: Not Specified
Max Power Capacity: 1600 W
Status: Present, Unknown
Type: Unknown
Input Voltage Range Switching: Unknown
Plugged: Yes
Hot Replaceable: Yes
Handle 0x2900, DMI type 41, 11 bytes
Onboard Device
Reference Designation: Embedded Video
Type: Video
Status: Enabled
Type Instance: 1
Bus Address: 0000:0b:00.0
Handle 0x2901, DMI type 41, 11 bytes
Onboard Device
Reference Designation: Embedded EHCI USB Controller 1
Type: Other
Status: Enabled
Type Instance: 1
Bus Address: 0000:00:1d.0
Handle 0x2902, DMI type 41, 11 bytes
Onboard Device
Reference Designation: Embedded EHCI USB Controller 2
Type: Other
Status: Enabled
Type Instance: 2
Bus Address: 0000:00:1a.0
Handle 0xB100, DMI type 177, 12 bytes
OEM-specific Type
Header and Data:
B1 0C 00 B1 00 02 00 00 00 00 00 00
Handle 0xD000, DMI type 208, 16 bytes
OEM-specific Type
Header and Data:
D0 10 00 D0 02 00 FE 00 B6 06 00 00 00 01 00 00
Handle 0xD200, DMI type 210, 12 bytes
OEM-specific Type
Header and Data:
D2 0C 00 D2 F8 02 03 03 06 80 04 05
Handle 0xD800, DMI type 216, 9 bytes
OEM-specific Type
Header and Data:
D8 09 00 D8 01 02 00 F0 03
Strings:
Matrox
{* Content TBD *}
Handle 0xDE00, DMI type 222, 16 bytes
OEM-specific Type
Header and Data:
DE 10 00 DE 00 40 FF FF 00 00 00 00 00 01 00 00
Handle 0xE100, DMI type 225, 13 bytes
OEM-specific Type
Header and Data:
E1 0D 00 E1 01 01 00 04 00 02 01 04 00
Strings:
CPU.Socket.1
CPU.Socket.2
Handle 0xE101, DMI type 225, 53 bytes
OEM-specific Type
Header and Data:
E1 35 01 E1 01 01 00 11 00 02 01 11 00 03 02 11
00 04 03 11 00 05 04 11 00 06 05 11 00 07 06 11
00 08 07 11 00 09 08 11 00 0A 09 11 00 0B 0A 11
00 0C 0B 11 00
Strings:
DIMM.Socket.A1
DIMM.Socket.A2
DIMM.Socket.A3
DIMM.Socket.A4
DIMM.Socket.A5
DIMM.Socket.A6
DIMM.Socket.A7
DIMM.Socket.A8
DIMM.Socket.B1
DIMM.Socket.B2
DIMM.Socket.B3
DIMM.Socket.B4
Handle 0xFEFF, DMI type 127, 4 bytes
End Of Table