Commit graph

25 commits

Author SHA1 Message Date
Christophe Simon
305d4d41ec Various changes
- Added an option to specify an SSL CA certificates file to talk to the
  Netbox API
- Enhanced GPU expansion bays inventory: internal GPU (VGA) goes into
  the blade, external GPU (3D) goes into the expansion bay
- Unified the way expansion bays are managed (GPU and drive exansion
  bays)
- Started to refactor `network` module to make it more readable
- Dependencies in `setup.py` now reads its requirements from
  `requirements.txt` to avoid double maintenance
2022-02-22 14:51:58 +01:00
Christophe Simon
5d9602402b
Merge branch 'master' into fix/chriss/purge_remaining_devices 2022-02-15 10:34:50 +01:00
Christophe Simon
2f09cf8d42 Manage blade expansions as independent devices
This patch adds the ability to detect and manage GPU and Disk expansion
bays, and either add their internal components into the device
corresponding to the blade server, or into a dedicated device.

It takes advantage of the work made by @cyrinux on GPU bays management, and
applies the same principle to the external disk bays, but harmonize the
inventory management:

- If no argument is specified on the command line, the GPU cards, RAID
  controllers and their attached disks are added in the blade device,
  and the device corresponding to an expansion device is deleted.
- If the `--expansion-as-device` option is specified on the command
  line, a dedicated device corresponding to the expansion bay is
  created, and the GPUs, RAID card and attached disks are removed from
  the blade device and added to the expansion device.
2022-02-14 14:37:02 +01:00
Christophe Simon
58775c0950 Added option to purge remaining devices
This patch adds an option to clear remaining devices in the context of a
new device replacing an old one with the same name but with a different
hardware.

The serial leading to the bug is described below:

- A first server is registered under name `A` with serial `X`
- A second server is registered under name `B` with serial `Y`
- The server with serial `X` is decomissionned, but not removed
- The server with serial `Y` is reinstalled with name `A`

In this case, a device with serial `X` is well found, and netbox agent
tries to update its name. But this raises an error because of the unique
constraint on name, as another device already holds this name.

The proposed solution to handle this situation is to delete any device
with same `name` but different `serial` before handling a device.

As this is not necessarily the expected behavior, it can be enabled by
using the `--purge-old-devices` to avoid breaking existing inventory.
2022-02-08 18:46:30 +01:00
Solvik Blum
9611400b22 move ssl_verify under 'netbox' config 2020-07-11 15:28:04 +02:00
Solvik Blum
53cb29a6d4 fix import order 2020-07-11 15:14:33 +02:00
strus38
70e5d407f5 Fix indentation 2020-07-08 22:19:39 +02:00
strus38
0894e645a8 Fix indentation 2020-07-08 10:02:45 +02:00
strus38
95d2ae420e Fix indentation 2020-07-08 09:47:48 +02:00
strus38
275e1850c6 Adding the --no_ssl_verify option to support Netbox connection with https and untrusted certificates 2020-07-08 09:36:13 +02:00
ThomasADavis
a60c0cd70c
Add tags,device roles,tenants.. (#110)
* Adds support for:

* sets the tenant for IP addresses and Devices.
* setting device tags
* setting the blade, chassis, and server roles.

Co-authored-by: Thomas Davis <tdavis@nersc.gov>
Co-authored-by: Solvik <solvik@solvik.fr>
2020-07-01 18:54:58 +02:00
Solvik
f06da32fc3
Virtual Machine feature (#122)
Add ability to create Virtual Machine in netbox with an auto-detecting feature (currently VirtualBox, Xen, Hyper-V, VMWare, GCP)

One caveat, I made the choice not to report the disk as Netbox model allow only one size but VM often have multiples.

Also, lot of code refactoring to be able to use create_or_update function style, fixing a lot of corner case
2020-04-19 12:28:49 +02:00
ramnes
bab2d26ad0 Setup tests 2020-02-02 20:24:01 +01:00
Solvik
5f851ec619
add config to set hostname command (#81) 2019-09-12 11:15:12 +02:00
Solvik
8d0168acb5
Add power supply support (#56) 2019-09-05 13:47:10 +02:00
Solvik
d12ac49d50
new config system (#53) 2019-09-03 13:16:37 +02:00
Solvik
0faee59bde
Supermicro server can guess their slot via the config file (#50) 2019-08-29 16:13:04 +02:00
Solvik
de3c59a675
Local inventory (#16)
- Create and update CPU
- Create and update Memory
- Create and update RAID Cards (HP and Storcli)
- Create and update Physical disks
2019-08-26 16:54:48 +02:00
Solvik
33c55340b7
Add LLDP auto cabling (#41) 2019-08-26 11:05:41 +02:00
Solvik
980f14236f
Fix late comments (#29)
* more fixes
* add external binary requirements
* better error handling for bonding
2019-08-09 13:26:51 +02:00
Solvik
2988a8bd6a
Rework all network part (#21)
* rework network part by ignoring devices and ip from config file

* update config file

* associate slave device to bond device with Netbox LAG

* update README

* make sure every interface attribute is ok

* some fixes after  test

* tox

* add ipmi feature

* fix bug in LAG

* ipmi class

* update README

* network update

* delete print

* update README
2019-08-09 12:08:11 +02:00
Solvik Blum
e8a9d318cc
simpler logging, log_level from config file 2019-08-07 10:32:23 +02:00
Solvik Blum
acbb767e22
rack awareness 2019-08-05 11:54:06 +02:00
Solvik Blum
6b24b4b000
add support for a datacenter driver in a separate file 2019-08-04 09:48:42 +02:00
Solvik Blum
8b8cd68ff2
add datacenter location awareness with pseudo-driver (cmd and file) 2019-08-04 01:21:20 +02:00