netbox-agent/netbox_agent/vendors/dell.py

70 lines
1.9 KiB
Python
Raw Normal View History

2019-09-05 13:47:10 +02:00
import logging
import subprocess
from netbox_agent.misc import is_tool
2020-02-02 20:08:56 +01:00
from netbox_agent.server import ServerBase
class DellHost(ServerBase):
def __init__(self, *args, **kwargs):
super(DellHost, self).__init__(*args, **kwargs)
self.manufacturer = 'Dell'
def is_blade(self):
return self.get_product_name().startswith('PowerEdge M')
def get_blade_slot(self):
"""
Return blade slot
dmidecode output is:
` Location In Chassis: Slot 03`
"""
if self.is_blade():
return self.baseboard[0].get('Location In Chassis').strip()
return None
2019-08-08 14:37:02 +02:00
def get_chassis_name(self):
if not self.is_blade():
return None
return 'Chassis {}'.format(self.get_service_tag())
def get_chassis(self):
if self.is_blade():
return self.chassis[0]['Version'].strip()
return self.get_product_name()
def get_chassis_service_tag(self):
if self.is_blade():
return self.chassis[0]['Serial Number'].strip()
return self.get_service_tag()
2019-09-05 13:47:10 +02:00
def get_power_consumption(self):
'''
Parse omreport output like this
Amperage
PS1 Current 1 : 1.8 A
PS2 Current 2 : 1.4 A
'''
value = []
if not is_tool('omreport'):
logging.error('omreport does not seem to be installed, please debug')
return value
data = subprocess.getoutput('omreport chassis pwrmonitoring')
amperage = False
for line in data.splitlines():
if line.startswith('Amperage'):
amperage = True
continue
if amperage:
if line.startswith('PS'):
amp_value = line.split(':')[1].split()[0]
value.append(amp_value)
else:
break
return value