Commit graph

53 commits

Author SHA1 Message Date
Michal Kazior
d9d5e55c54 DPP: Respond to GAS on the same channel it was received on
When I was testing dpp_auth_init on an AP with Enrollee on a different
channel from the AP I was getting failures. This happened on hwsim in
UML with time-travel for me. I don't recall seeing this with real
devices, presumably because of lax offchan implementation.

The DPP authentication would succeed. However the station would then try
to get configuration through a GAS request and fail.

The AP reported the following logs (grepped):

> 1614762426.860212: RX_ACTION category 4 action 10 sa 02:00:00:00:01:00 da 02:00:00:00:00:00 len 227 freq 2412
> 1614762426.860212: wlan0: GAS: GAS Initial Request from 02:00:00:00:01:00 (dialog token 239)
> 1614762426.860233: DPP: Wait for Configuration Result
> 1614762426.860234: nl80211: Send Action frame (ifindex=5, freq=2462 MHz wait=0 ms no_cck=0 offchanok=0)
> 1614762428.861186: DPP: Timeout while waiting for Configuration Result
> 1614762428.861186: wlan0: DPP-CONF-FAILED

While the STA reported the following logs (grepped):

> 1614762426.860193: wlan1: DPP-AUTH-SUCCESS init=0
> 1614762426.860195: DPP: Stop listen on 2412 MHz
> 1614762426.860202: wlan1: GAS-QUERY-START addr=02:00:00:00:00:00 dialog_token=239 freq=2412
> 1614762428.861185: GAS: No response received for query to 02:00:00:00:00:00 dialog token 239
> 1614762428.861189: DPP: GAS query did not succeed
> 1614762428.861189: wlan1: DPP-CONF-FAILED

AP would still receive the GAS request on ch1 but would then try to
respond on ch11 while STA was waiting on ch1.

Signed-off-by: Michal Kazior <michal@plume.com>
2022-12-18 21:07:56 +02:00
Disha Das
5c6c0d569a DPP: Fix GAS fragmentation for DPP Config Response from hostapd
The Query Response Length field was missing from GAS Initial Response
and GAS Comeback Response frames in the DPP specific code path from
hostaps GAS server. This resulted in invalid frames being used when the
DPP Config Response needed fragmentation. Fix this by adding the Query
Response Length fields into these frames.

Signed-off-by: Disha Das <dishad@codeaurora.org>
2020-10-06 23:34:41 +03:00
Jouni Malinen
e00f780e2b DPP2: hostapd as TCP Relay
The new hostapd configuration parameter dpp_controller can now be used
with the following subparameter values: ipaddr=<IP address>
pkhash=<hexdump>. This adds a new Controller into the configuration
(i.e., more than one can be configured) and all incoming DPP exchanges
that match the specified Controller public key hash are relayed to the
particular Controller.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-04-22 21:08:59 +03:00
Jouni Malinen
cad810a98f HS 2.0: OSU Provider NAI List advertisement
Extend hostapd to allow the new OSU Provider NAI List ANQP-element to be
advertised in addition to the previously used OSU Providers list
ANQP-element. The new osu_nai2 configurator parameter option is used to
specify the OSU_NAI value for the shared BSS (Single SSID) case while
osu_nai remains to be used for the separate OSU BSS.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-10-05 20:49:42 +03:00
Jouni Malinen
0e450db285 HS 2.0: Allow configuration of operator icons
This extends hostapd Hotspot 2.0 implementation to allow operator icons
to be made available. The existing hs20_icon parameter is used to define
the icons and the new operator_icon parameter (zero or more entries) is
used to specify which of the available icons are operator icons. The
operator icons are advertised in the Operator Icon Metadata ANQP-element
while the icon data can be fetched using the same mechanism (icon
request/binary file) that was added for the OSU Providers icons.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-04-17 16:40:47 +03:00
Jouni Malinen
7e1d3ee963 Add hostapd.conf venue_url to set Venue URL ANQP-element
The new venue_url parameter can now be used to set the Venue URL ANQP
information instead of having to construct the data and use
anqp_elem=277:<hexdump> to set the raw value.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2018-03-26 16:10:47 +03:00
Jouni Malinen
634a130a52 DPP: Clear authentication instance on configuration completion in AP
wpa_supplicant was already doing this and hostapd needs to clear
hapd->dpp_auth when completing the exchange in Configurator (GAS server)
role.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-11-27 20:33:43 +02:00
Andrei Otcheretianski
bfbc41eace DPP: Fix compilation without openssl
dpp.h file requires openssl in order to compile, which breaks
compilation on systems without it.
Move DPP_OUI_TYPE to ieee802_11_defs.h and don't include dpp.h when
not really needed.

Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
2017-07-07 23:37:45 +03:00
Jouni Malinen
2605405aa4 DPP: Configurator in hostapd
This integrates DPP configuration request processing into hostapd GAS
server implementation.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-07-03 13:03:35 +03:00
Jouni Malinen
f541148257 Fix GAS server ifdef block use
Commit 941caed980 ('MBO: Add MBO
ANQP-element processing on AP') changed the design by using the
rx_anqp_vendor_specific() function to process all ANQP vendor specific
elements. However, the caller for this was within ifdef CONFIG_HS20
block. Fix this by calling the function even in CONFIG_HS20=y is not
included in the build. This fixes CONFIG_MBO=y builds without
CONFIG_HS20=y.

Signed-off-by: Jouni Malinen <j@w1.fi>
2017-05-01 17:39:14 +03:00
Jouni Malinen
941caed980 MBO: Add MBO ANQP-element processing on AP
This extends the GAS server to process MBO ANQP-elements and reply to a
query for the Cellular Data Connection Preference (if configured). The
new configuration parameter mbo_cell_data_conn_pref can be used to set
the value (0, 1, or 255) for the preference to indicate.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-03-10 18:33:51 +02:00
Jouni Malinen
65ab7eb1fa GAS: Fix OSU Providers List response with invalid configuration
If the OSU Providers configuration was invalid (included osu_server_uri
but not osu_method_list), it was possible for the GAS response
generation to hit a NULL dereference. Fix this by checking for the
invalid configuration before trying to fill in the OSU methods.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2017-02-07 17:47:58 +02:00
Daniel Kim
4cc61c3866 GAS: Set temporary session timeout bigger than gas_comeback_delay
Previously, the temporary STA session timeout was set to 5 seconds. If
gas_comeback_delay is configured to be longer than 5 seconds, GAS
Comeback Response frame can't include queried information as all pending
data has already been cleared due to session timeout. This commit
resolves the issue by setting session timeout to be larger than
gas_comeback_delay.

Signed-off-by: Daniel Kim <kimdan@qca.qualcomm.com>
2017-01-30 13:25:48 +02:00
Jouni Malinen
aeff0645d2 FILS: Fix FILS Realm Information ANQP-element construction
The loop to add hash values was supposed to be limited to at most 10000
values, but the count variable was not being decremented in the loop.
Fix this by decrementing counting for each iteration. This fixes
ANQP-element format in the unlikely case of there being more than 10000
configuration realms.

Signed-off-by: Jouni Malinen <j@w1.fi>
2017-01-03 15:18:30 +02:00
Jouni Malinen
2977f5193a GAS: Remove unnecessarily duplicate gas_frag_limit configuration
The actual BSS configuration parameter can be updated with the SET
control interface command, so there is no need to maintain a separate
per-BSS parameter and a separate control interface handling for this.

Signed-off-by: Jouni Malinen <j@w1.fi>
2016-12-30 00:23:10 +02:00
Jouni Malinen
8183aee6cc FILS: Add support for building FILS Realm Information ANQP-element
This allows full list of hashed realm names to be fetched from hostapd.

Signed-off-by: Jouni Malinen <j@w1.fi>
2016-12-18 11:41:59 +02:00
Jouni Malinen
4051dd8667 GAS: Add Capability List ANQP-element support for Info ID 270, 280..299
This extends the anqp_elem configuration parameter support for new Info
IDs (270 (TDLS Capability) was previously missed from the list of
defined values, 280 has already been assigned in REVmc/D8.0; 281..299
are yet to be assigned). No additional source code changes are needed to
allow hostapd to advertise support for these if the ANQP-element value
is set with the anqp_elem parameter.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2016-11-17 16:00:25 +02:00
Jouni Malinen
8359472589 hostapd Make GAS Address3 field selection behavior configurable
gas_address3=1 can now be used to force hostapd to use the IEEE 802.11
standards compliant Address 3 field value (Wildcard BSSID when not
associated) even if the GAS request uses non-compliant address (AP
BSSID).

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2016-06-10 22:13:37 +03:00
Jouni Malinen
78a3632765 hostapd: Fix Public Action frame addressing (BSSID field)
IEEE Std 802.11-2012, 10.19 (Public Action frame addressing) specifies
that the wildcard BSSID value is used in Public Action frames that are
transmitted to a STA that is not a member of the same BSS. hostapd used
to use the actual BSSID value for all such frames regardless of whether
the destination STA is a member of the BSS.

Fix this by using the wildcard BSSID in cases the destination STA is not
a member of the BSS. Leave group addressed case as-is (i.e., the actual
BSSID), since both values are accepted. No such frames are currently
used, though.

This version is still using the AP BSSID value in the Address 3 field
for GAS response frames when replying to a GAS request with AP BSSID
instead of Wildcard BSSID. This is left as a workaround to avoid
interoperability issues with deployed STA implementations that are still
using the non-compliant address and that might be unable to process the
standard compliant case.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2016-06-10 21:44:49 +03:00
Max Stepanov
d179089b6d GAS: Calculate response buffer length of ANQP elements
Calculate the required length needed for the extra ANQP elements added
to GAS response buffer instead of using fixed size and truncating the
response if there was not sufficient space.

Signed-off-by: Max Stepanov <Max.Stepanov@intel.com>
2016-02-06 01:19:32 +02:00
Jouni Malinen
a587666cba GAS server: Replenish temporary STA entry timeout on comeback request
Previously, the five second timeout was added at the beginning of the
full GAS query and it was not replenished during fragmented exchanges.
This could result in timing out a query if it takes significant time to
go through the possibly multiple fragments and long comeback delay.

Signed-off-by: Jouni Malinen <j@w1.fi>
2015-12-20 19:43:23 +02:00
Jouni Malinen
f88bcad015 GAS server: Avoid undefined behavior in pointer arithmetic
Reorder terms in a way that no invalid pointers are generated with
pos+len operations. end-pos is always defined (with a valid pos pointer)
while pos+len could end up pointing beyond the end pointer which would
be undefined behavior.

Signed-off-by: Jouni Malinen <j@w1.fi>
2015-10-25 15:34:59 +02:00
Jouni Malinen
695dbbea88 Interworking: Add support for configuring arbitrary ANQP-elements
The new hostapd configuration parameter anqp_elem can now be used to
configure arbitrary ANQP-elements for the GAS/ANQP server. In addition
to supporting new elements, this can be used to override previously
supported elements if some special values are needed (mainly for testing
purposes).

The parameter uses following format:
anqp_elem=<InfoID>:<hexdump of payload>

For example, AP Geospatial Location ANQP-element with unknown location:
anqp_elem=265:0000
and AP Civic Location ANQP-element with unknown location:
anqp_elem=266:000000

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2015-10-07 17:07:21 +03:00
Jouni Malinen
faebdeaa9e Use os_calloc() instead of os_zalloc()
Automatic changes with spatch using the following semantic patch:

@@
constant C;
type T;
@@

- os_zalloc(C*sizeof(T))
+ os_calloc(C,sizeof(T))

@@
expression E;
type T;
@@

- os_zalloc((E)*sizeof(T))
+ os_calloc(E,sizeof(T))

Signed-off-by: Jouni Malinen <j@w1.fi>
2014-12-08 11:42:07 +02:00
Jouni Malinen
a6b1215769 GAS: Do not reply to P2P SD query from generic GAS/ANQP server
This avoids an issue where a wpa_supplicant build with CONFIG_P2P=y and
CONFIG_HS20=y ended up processing a P2P SD query twice when operating as
a GO and sending out two replies. Only the P2P SD implementation should
reply to P2P SD query in such a case.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2014-10-22 19:21:42 +03:00
Jouni Malinen
062833c67c GAS server: Fix request frame length validation (CID 68098)
There seemed to be an off-by-one error in the validation of GAS request
frames. If a Public Action frame without the Action code field would
have reached this function, the length could have been passed as
(size_t) -1 which would likely have resulted in a crash due to reading
beyond the buffer. However, it looks like such frame would not be
delivered to hostapd at least with mac80211-based drivers. Anyway, this
function better be more careful with length validation should some other
driver end up reporting invalid Action frames.

In addition, the Action code field is in a fixed location, so the
IEEE80211_HDRLEN can be used here to clean up bounds checking to avoid
false reports from static analyzer.

Signed-off-by: Jouni Malinen <j@w1.fi>
2014-06-13 00:27:15 +03:00
Jouni Malinen
1fde15a20a GAS server: Explicitly check that home realm is available
This makes the code easier to understand for static analyzers to avoid
false reports.

Signed-off-by: Jouni Malinen <j@w1.fi>
2014-06-07 19:05:33 +03:00
Jouni Malinen
aff0bee78a GAS server: Remove unused function parameter
This parameter was not used at all, so just remove the argument instead
of passing NULL.

Signed-off-by: Jouni Malinen <j@w1.fi>
2014-06-07 19:04:17 +03:00
Jouni Malinen
d73c7b9626 GAS: Send error response if no room for pending dialog context
Instead of silently dropping the response that requires fragmentation,
send an error response to the station to make it aware that no full
response will be available.

Signed-off-by: Jouni Malinen <j@w1.fi>
2014-05-26 17:21:43 +03:00
Jouni Malinen
d0bf06f2d9 GAS server: Remove incomplete remote ANQP processing
Some of the remote ANQP server concepts were introduces into gas_serv.c,
but these were not completed. Remote the unused implementation for now.
It can be added back if support for remote ANQP server is added at some
point.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>
2014-03-13 21:12:39 +02:00
Jouni Malinen
ae6d15c722 HS 2.0R2 AP: Add OSU Providers list ANQP element
hostapd can now be configured to advertise OSU Providers with the
new osu_* confgiuration parameters.

Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2014-02-26 01:24:25 +02:00
Jouni Malinen
f7bd7a01a8 HS 2.0R2 AP: Add Icon Request and Icon binary File ANQP elements
hostapd can now be configured to provide access for icon files
(hs20_icon config file parameter) for OSU. The hs20_icon data contains
additional meta data about the icon that is not yet used, but it will be
needed for the OSU Providers list ANQP element.

Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2014-02-26 01:24:25 +02:00
Jouni Malinen
5ce00d09c0 GAS server: Add support for Protected Dual of Public Action frames
When GAS is used with PMF negotiated, Protected Dual of Public Action
frames are expected to be used instead of Public Action frames, i.e.,
the GAS/ANQP frames are expected to be encrypted. Add support for this
different category of Action frames being used for GAS. The payload
after the Category field is identical, so the only change is in using
the Category field based on what was received in the request frames. For
backwards compatibility, do not enforce protected dual to be used on the
AP side, i.e., follow what the station does.

Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2014-01-23 11:19:55 +02:00
Kyeyoon Park
91f9e6078f GAS: Replenish AP station session timer to 5 seconds
If remaining AP session timeout is less than 5 seconds
for an existing station, replenish the timeout to 5 seconds.
This allows stations to be able to recycle a dialog token
value beyond 5 seconds for GAS exchange.

Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2013-11-08 00:22:32 +02:00
Jouni Malinen
2d9ffe1e85 P2P: Fix Action frame processing if Interworking is enabled
GAS server used the same public_action_cb mechanism as P2P to process
Action frames. This ended up overriding P2P processing of Action frames
while running an AP/GO interface with a build that enables Interworking
(e.g., for Hotspot 2.0) and a driver that uses hostapd for AP mode
SME/MLME. Fix this by adding a separate callback registration for the
GAS server. This should really be cleaned up by supporting arbitrary
number of callback handlers, but for now, this addresses the regression
with a minimal change.

Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2013-02-04 15:38:35 +02:00
Jouni Malinen
ce6ce7fb13 hostapd: Fix CONFIG_INTERWORKING=y build without CONFIG_HS20=y
Signed-hostap: Jouni Malinen <j@w1.fi>
2012-09-15 22:37:27 -07:00
Jay Katabathuni
43f51e2aa0 HS 2.0: Add NAI Home Realm query
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2012-08-26 18:59:15 +03:00
Jay Katabathuni
8047b18691 Interworking: Add advertising of NAI Realm list
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2012-08-26 18:59:12 +03:00
Jay Katabathuni
a9277e85ca HS 2.0: Add advertisement of Operator Friendly Name
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2012-08-25 21:39:19 +03:00
Jouni Malinen
1792e58dbb Interworking: Use generic language,string parser
Replace the Venue Name specific data structure and parser with a
generic mechanism that can be used with other fields that use the
same format.

Signed-hostap: Jouni Malinen <j@w1.fi>
2012-08-25 21:39:00 +03:00
Jay Katabathuni
4065a3092b HS 2.0: Add advertisement of WAN Metrics
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2012-08-25 20:28:40 +03:00
Jay Katabathuni
5ccc54aae4 HS 2.0: Add advertisement of Connection Capability
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2012-08-25 19:16:09 +03:00
Jay Katabathuni
df5934f194 HS 2.0: Add advertising of Operating Class Indication
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2012-08-25 18:26:32 +03:00
Jay Katabathuni
7515adb2b1 Interworking: Add advertising of 3GPP Cellular Network info
The anqp_3gpp_cell_net parameter can be used to configure hostapd
to advertise 3GPP Cellular Network ANQP information.

Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2012-08-25 18:26:28 +03:00
Jouni Malinen
771e2f7b33 GAS server: Add forgotten break statement to a switch case
Signed-hostap: Jouni Malinen <j@w1.fi>
2012-08-07 15:46:26 +03:00
Jay Katabathuni
45ac307a2b HS 2.0: Add HS Capability element (AP)
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2012-07-30 22:25:23 +03:00
Jay Katabathuni
26fac8b6a0 Interworking: Add Domain Name element (AP)
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2012-07-30 22:25:19 +03:00
Jay Katabathuni
78bda93e83 Interworking: Add IP Address Type Availability element (AP)
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2012-07-30 22:25:16 +03:00
Jay Katabathuni
550a3958f7 Interworking: Add Network Auth Type element (AP)
Signed-hostap: Jouni Malinen <jouni@qca.qualcomm.com>
2012-07-30 22:25:14 +03:00
Jouni Malinen
d84b913955 Remove unused variable
Signed-hostap: Jouni Malinen <j@w1.fi>
2012-04-28 18:30:41 +03:00