Commit graph

4372 commits

Author SHA1 Message Date
Veerendranath Jakkam
08512e5f35 MLD STA: Extend key configuration functions to support Link ID
Add support to specify a Link ID for set key operation for MLO
connection. This does not change the existing uses and only provides the
mechanism for extension in following commits.

Signed-off-by: Veerendranath Jakkam <quic_vjakkam@quicinc.com>
2022-11-06 23:36:49 +02:00
Jouni Malinen
66d7f554e2 tests: Fuzz testing for PASN
Add test tools for fuzzing PASN initiator and responder handling of
received PASN Authentication frames.

Signed-off-by: Jouni Malinen <j@w1.fi>
2022-11-06 17:22:14 +02:00
Jouni Malinen
2e840fb2ab tests: Fix CC and CFLAGS default processing for fuzzing
"make LIBFUZZER=y" was supposed to set CC and CFLAGS to working values
by default if not overridden by something external. That did not seem to
work since the defaults from the other build system components ended up
setting these variables before the checks here. Fix this by replacing
the known default values for non-fuzzing builds.

Signed-off-by: Jouni Malinen <j@w1.fi>
2022-11-06 17:11:47 +02:00
Jeffery Miller
c6f8af507e Add option to disable SAE key_mgmt without PMF
Add the `sae_check_mfp` global option to limit SAE when PMF will
not be selected for the connection.
With this option SAE is avoided when the hardware is not capable
of PMF due to missing ciphers.
With this option SAE is avoided on capable hardware when the AP
does not enable PMF.

Allows falling back to PSK on drivers with the
WPA_DRIVER_FLAGS_SAE capability but do not support the BIP cipher
necessary for PMF. This enables configurations that can fall back
to WPA-PSK and avoid problems associating with APs configured
with `sae_require_mfp=1`.

Useful when `pmf=1` and `sae_check_mfp=1` are enabled and networks
are configured with ieee80211w=3 (default) and key_mgmt="WPA-PSK SAE".
In this configuration if the device is unable to use PMF due to
lacking BIP group ciphers it will avoid SAE and fallback to
WPA-PSK for that connection.

Signed-off-by: Jeffery Miller <jefferymiller@google.com>
2022-11-05 17:48:17 +02:00
Jouni Malinen
a3094ef80d tests: Allow more time for sigma_dut sta_reassoc commands
When these are issued while associated, scanning all channels can take a
significant amount of time. That happened to work for existing test
cases somewhat by accident since the scan was sometimes limited to only
the current operating channel. However, that is now changing and the
following two test cases started failing with the change, so make them
wait longer:
sigma_dut_sae_pw_id_ft sigma_dut_ft_rsnxe_used_mismatch

Signed-off-by: Jouni Malinen <j@w1.fi>
2022-11-05 13:43:06 +02:00
Shivani Baranwal
ef10a574d6 tests: P2P persistent group formation with extended listen
Add a new P2P persistent group formation, re-invocation, and cancel test
to verify that P2P_EXT_LISTEN is avoided and the scan is performed in
the P2P Client role to find the P2P GO for the ongoing P2P persistent
group formation on the current interface.

Signed-off-by: Shivani Baranwal <quic_shivbara@quicinc.com>
2022-11-05 12:17:23 +02:00
Jouni Malinen
ab22b676a5 tests: FT-SAE-EXT-KEY
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-10-16 17:43:38 +03:00
Jouni Malinen
2e0400061f tests: wpa_supplicant AP mode with pmf=1/2
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-10-10 12:34:04 +03:00
Jouni Malinen
97104a6588 tests: Clear sae_groups when SAE could be used
This makes sigma_dut_ap_dpp_qr* test cases with SAE more robust by
avoiding unexpected behavior. This was found with the following test
sequence:
mesh_sae_anti_clogging sigma_dut_ap_dpp_qr_sae

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-10-07 20:59:34 +03:00
Jouni Malinen
db46138de4 tests: sigma_dut DPP reconfiguration using SAE (Enrollee)
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-10-07 19:44:48 +03:00
Jouni Malinen
5007766d78 tests: Clear vendor elements at the end of wpas_ap_vendor_elems
This is needed to avoid surprises in the following test cases. This was
found with a failure in the following test sequence:
wpas_ap_vendor_elems p2p_ext_discovery_go

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-10-05 00:22:52 +03:00
Jouni Malinen
56321c0ac2 tests: Make sigma_dut_dpp_qr_mutual_resp_enrollee_connector_privacy more robust
Clear the dpp_connector_privacy_default parameter value that sigma_dut
set in wpa_supplicant at the end of the test case to avoid surprising
behavior for the following test cases. This was found with a failure in
the following test sequence:
sigma_dut_dpp_qr_mutual_resp_enrollee_connector_privacy
sigma_dut_dpp_proto_peer_disc_req

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-10-05 00:22:27 +03:00
Jouni Malinen
ca94fd70c8 tests: sigma_dut and DPP AP provisioning with SAE
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-10-03 19:20:21 +03:00
Jouni Malinen
14cc63295e tests: DPP AP configuration for SAE-only
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-10-03 12:34:16 +03:00
Jouni Malinen
6ef455db67 tests: Automatic channel selection and 2.4 GHz channel 14
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-09-23 00:25:24 +03:00
Jouni Malinen
f47d378cea tests: P2P and avoid frequencies preventing 80 MHz on channel 149"
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-09-23 00:12:33 +03:00
Johannes Berg
c52ec086da tests: hwsim: Search for UBSAN in kernel messages
If UBSAN is enabled, flag errors from it.

Signed-off-by: Johannes Berg <johannes.berg@intel.com>
2022-09-16 21:39:44 +03:00
Johannes Berg
550ab94e83 tests: vm: Simplify parameter passing
Since the kernel  actually passes the command-line parameters
as environment variables to the init script, there's no need
to parse them out of /proc/cmdline.

Signed-off-by: Johannes Berg <johannes.berg@intel.com>
2022-09-16 21:28:23 +03:00
Johannes Berg
6f90aa5a63 tests: hwsim: Allow configuring MODULEDIR
It can be useful to configure a different module directory, so you don't
need to install the kernel modules in the host /lib/modules/ location.
Allow configuring it in the config file.

Signed-off-by: Johannes Berg <johannes.berg@intel.com>
2022-09-16 21:16:10 +03:00
Johannes Berg
6f844fa787 tests: Reload correct regdb if possible/needed
If cfg80211 is built into the kernel, then it may/will have
loaded the regdb before we mount our own /lib/firmware. This
may result in using the wrong regulatory data. Fix this by
using iw to reload the regdb after mounting it.

Fixes: a29c2399a7 ("tests: Add regulatory database to VMs")
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
2022-09-16 21:13:20 +03:00
Jouni Malinen
a01266c925 tests: sigma_dut and EAP-AKA with imsiPrivacyCertID
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-09-14 20:31:55 +03:00
Jouni Malinen
01e7acc747 tests: DPP push button and unsupported AP configuration
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-08-27 00:51:25 +03:00
Jouni Malinen
05d3681f3e tests: Skip sigma_dut_dpp_tcp_configurator_init_mutual_unsupported_curve if needed
The part about checking the supported curves from the peer depends on
CONFIG_DPP3 and this test case needs to be skipped without that.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-08-26 17:27:45 +03:00
Jouni Malinen
d6e790e209 tests: DPP PB channel changes
Prepare for an implementation change for the PB discovery channel list.
Move the standlone (not an AP) PB Configurators to a preferred channel
and enable Configurator connectivity indication in APs that act as PB
Configurators.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-08-25 15:59:13 +03:00
Jouni Malinen
d68946d510 tests: sigma_dut and DPP push button first on Enrollee
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-08-23 18:56:17 +03:00
Jouni Malinen
b704dc72ef tests: sigma_dut and updated ConfResult value for Configurator failures
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-29 18:56:49 +03:00
Jouni Malinen
10104915af tests: sigma_dut and DPP PB session overlap
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-28 21:17:15 +03:00
Jouni Malinen
8adcdd6593 tests: Temporary workaround for dpp_chirp_ap_5g
Configurator station seems to be unable to get the first Authentication
Request frame transmitted through mac80211_hwsim for some reason. It is
not really clear why this happens and why it started happening now, but
as a temporary workaround, wait a second here since that seems to avoid
this for some unknown reason.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-28 17:58:01 +03:00
Jouni Malinen
ddcd15c2de tests: Fix fuzzing/sae build
sae.c depends on wpa_common.c now and as such, this test build needs to
pull in whatever is needed there and that happens to include sha1-prf.c.
Add that to the fuzzer to fix the build.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-28 17:08:11 +03:00
Jouni Malinen
7fa67861ae tests: Fix p2p_channel_avoid3
This test case assumed that the p2p_pref_chan 128:44 parameter would
have resulted in channel 44 (5220 MHz) being selected. That does not
work anymore since that channel was marked to require DFS/radar
detection in regdb. Fix the text case by changing to use another country
with rules that match the test case expectations.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-28 16:56:21 +03:00
Jouni Malinen
ee3567d659 tests: Add more time for scan/connection
It looks like some test cases could fail due to timeouts since the 10
second wait may not be sufficient to cover some cases where 6 GHz
channels get scanned. Increase the timeouts to avoid hitting such cases.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-28 16:41:23 +03:00
Jouni Malinen
ac9e6a2ab3 tests: Allow 6 GHz opclasses in MBO checks
It looks like the host update of regulatory information can still get
through somehow, so add alternative expected values for the supported
operating classes for cases where 6 GHz frequencies were added recently.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-28 16:39:41 +03:00
Jouni Malinen
e7cbfa1c12 tests: sigma_dut and DPP Enrollee unsupported curves
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-28 11:22:44 +03:00
Jouni Malinen
ceae05cec2 tests: sigma_dut and DPP MUDURL setting for hostapd
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-27 13:43:58 +03:00
Jouni Malinen
2a9a61d6cd tests: SAE with extended key AKM
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-25 11:12:11 +03:00
Jouni Malinen
e35f6ed1d4 tests: More detailed report on SAE PMKSA caching error case
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-25 00:31:51 +03:00
Jouni Malinen
35587fa8f3 tests: DPP Controller/Relay with need to discover Controller
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-25 00:23:31 +03:00
Jouni Malinen
ca7892e98f tests: DPP Relay and adding/removing connection to a Controller
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-25 00:23:31 +03:00
Jouni Malinen
ff7cc1d490 tests: DPP Relay and dynamic Controller addition
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-23 16:58:00 +03:00
Jouni Malinen
b607d2723e tests: sigma_dut and DPP PB Configurator in wpa_supplicant
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-22 12:39:58 +03:00
Jouni Malinen
b94e46bc71 tests: PB Configurator in wpa_supplicant
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-22 12:27:24 +03:00
Jouni Malinen
ca4e82cbfe tests: sigma_dut DPP/PKEX initiator as Configurator over TCP and Wi-Fi
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-21 20:32:32 +03:00
Jouni Malinen
dfa9183b11 tests: DPP reconfig after Controller-initiated operation through Relay
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-21 13:16:26 +03:00
Jouni Malinen
17216b5242 tests: sigma_dut DPP/PKEX initiator as Configurator (TCP) through Relay
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-19 23:28:33 +03:00
Jouni Malinen
d86ed5b72b tests: Allow DPP_PKEX_REMOVE success in dpp_pkex_hostapd_errors
This is in preparation to allow the implementation in hostapd to be
changed to accept removal of PKEX information without indicating an
error after it have been automatically removed at the successful
completion of PKEX.

Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-19 23:28:33 +03:00
Jouni Malinen
0a4f391b1c tests: sigma_dut and DPP Connector Privacy
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-19 00:14:41 +03:00
Jouni Malinen
7d12871ba0 test: DPP Private Peer Introduction protocol
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-19 00:14:41 +03:00
Jouni Malinen
f2bb0839fb test: DPP 3rd party config information
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-16 17:22:23 +03:00
Jouni Malinen
004b1ff47a tests: DPP Controller initiating through Relay
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-09 13:09:04 +03:00
Jouni Malinen
248654d36b tests: sigma_dut DPP PB test cases
Signed-off-by: Jouni Malinen <quic_jouni@quicinc.com>
2022-07-08 14:26:56 +03:00