Use a helper function to perform this common sequence to disconnect and
stop any possibly started reconnection attempt.
Signed-off-by: Jouni Malinen <j@w1.fi>
If the ABORT_SCAN command succeeds, CTRL-EVENT-SCAN-RESULTS event is
delivered for the aborted scan. Following this with an immediate
flush_scan_cache() call can result in the first scan interpreting that
pending event as the completion and that results in trying to start
another scan while the first scan is still in progress.
Signed-off-by: Jouni Malinen <j@w1.fi>
This is needed to avoid leaving behind a ROC operation at the end of the
test case. This was found with the following test sequence:
p2p_ext_vendor_elem_invitation wifi_display_r2
Signed-off-by: Jouni Malinen <j@w1.fi>
Parsing of the DER encoded signature was unable to handle results that
were shorter than the prime. These need to be zero padded from left to
generate the correct value.
Signed-off-by: Jouni Malinen <j@w1.fi>
The long wait for the monitor socket events resulted in another socket
running out of TX buffer space. Split the wait into smaller segments and
clear the other socket in each iteration.
Signed-off-by: Jouni Malinen <j@w1.fi>
Do not leave all the event messages pending in the socket queue for the
full duration of the test case to avoid hitting the TX socket queue
limit.
Signed-off-by: Jouni Malinen <j@w1.fi>
Some of the test cases left behind attached control interface monitor
sockets that could result in hitting the wpa_supplicant socket TX queue
limit. Try to be a bit more careful about detaching and closing the
sockets to avoid this.
Signed-off-by: Jouni Malinen <j@w1.fi>
The "_ipv6" part of the file name was missing and this resulted in file
names that conflicted with the IPv4 test cases and could overwrite logs
for those.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
It does not look like there would be two CTRL-EVENT-ASSOC-REJECT events
here, so only check the first one instead of requiring both to be
received with status_code=27. This test case could fail based on the
second connection attempt (due to that extra event wait) timing out.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Print a list of full paths to log files from failed test cases both the
parallel.log and stdout so that they can be easily opened for analysis.
In addition, renumber the VM lines in the <timestamp>-parallel.log to
match the i+1 numbering used in the log directories and UI that is
tracking test execution.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
One of the steps that expected failure due to PMKID mismatch did not
stop connection attempts. This could result in the following test step
failing due to the previous profile with peaplabel=1 getting used to
derive the MSK incorrectly.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The wait_event() call for scan completion could have processed a
previously received event from a prior scan instead of the newly started
one. This could result in flush_scan_cache() assuming there are still
results in the cache even though the scan request to clear the cache had
not even be started yet.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Use more readable "foo not in bar" construction for the couple of places
that did "not foo in bar".
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Prior cleanup broke the indentation here and made the addition of test
cases unreachable.
Fixes: 0663ae22ff ("tests: Do not use tabs for indentation")
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The new DPP Configuration Result message can result in a bit different
behavior at the end of the configuration exchange and some of the test
cases need more flexibility to work with that DPP2 behavior.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
gas_address3 was set to 1 in this test case, but it was never cleared.
That can result in unexpected behavior in other test cases that dpeends
on gas_address3 being in its default value 0. Clear the parameter
explicitly to avoid this.
This resulted in an error in the following test sequence:
dpp_qr_code_auth_initiator_enrollee gas_anqp_address3_ap_forced
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
There was a race condition on starting the flush_scan_cache() operations
if a scan happened to be in progress when the test case ended since the
ABORT_SCAN success case did not wait for the pending scan operation to
be completed. Wait for the scan completion event in addition to the
disconnection event if the ABORT_SCAN command is accepted.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
There was a race condition on starting the flush_scan_cache() operations
if a scan happened to be in progress when the test case ended since the
ABORT_SCAN success case did not wait for the pending scan operation to
be completed. Wait for the scan completion event in addition to the
disconnection event if the ABORT_SCAN command is accepted.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
These TDLS test cases missed Popen() result decode() calls in the
earlier python3 compatibility changes. Add those to make debug log more
readable.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Wait explicitly for the DPP-NOT-COMPATIBLE event when going through
protocol testing with local failures instead of just waiting for a fixed
0.1 second duration. This prevents a test failure at least in
dppauth_resp_status_failure in a case where the failing operation may be
delayed under heavy CPU load.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Test case sequence "ap_wps_ap_scan_2 ap_wps_pbc_2ap" resulted in a
failure due to a scan entry being left behind from the first test case
and the second one ending up using that obsolete result during WPS_PBC
processing. Fix this by clearing the scan results explicitly on dev5.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Accept a smaller number of token responses in second round to avoid
failing this test case as frequently.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The configurated fragmentation/RTS threshold value survives AP mode
interface restarts, so these values need to be explicitly cleared back
to default (disabled). This fixes an issue where some test cases could
not work correctly if fragmentation on the interface was enabled. For
example, this combination used to fail:
ap_fragmentation_open ap_hs20_fetch_osu
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The first scan for the unknown BSSID could have been timed in a manner
that allows passive scanning to find the real AP even if that AP's
beacon interval was 1000 (e.g., heavy CPU load changed timing so that
the AP beaconing started at suitable time). The check for BSS result
entry not including Probe Response frame was comparing incorrect BSS
entries (bss2 vs. bss1) which resulted in the test case claiming failure
even when there was no unexpected Probe Response frame.
Fix this by comparing the beacon_ie and ie parameters from the same BSS
entry (bss1).
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Number of these test cases start connection attempt in wpa_supplicant
and then expected a specific failure to happen relatively quickly. This
could result in timeouts if the first scanning round missed to find the
AP (e.g., due to CPU load pushing out the Probe Response frame long
enough for the station having left the channel) and wpa_supplicant then
waiting five seconds before starting a new scan.
Make this more robust by scanning explicitly for the specific BSSID
before starting the connection attempt.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This old interface has been obsoleted and should not have been used
since 2010, so remove testing for it in preparation to dropping the
interface completely from wpa_supplicant.
Signed-off-by: Lubomir Rintel <lkundrak@v3.sk>
No need to duplicate this functionality when all the ap_ft_pmf_*_over_ds
test cases are doing practically the same thing and the
no-specific-cipher-configuration case can be addressed easily with the
same helper function.
Signed-off-by: Jouni Malinen <j@w1.fi>
The main step of the test case was accidentally removed when adding the
cipher specific versions.
Fixes: ffcaca68d3 ("tests: FT with different BIP algorithms")
Signed-off-by: Jouni Malinen <j@w1.fi>
Configure the sae_groups parameter for hostapd explicitly in preparation
for the default value change in the implementation.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Configure the sae_groups parameter for hostapd explicitly in preparation
for the default value change in the implementation.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Avoid an invalid failure case due to scan results being left behind from
connect_cmd_bssid_hint when executing connect_cmd_reject_assoc by
explicitly clearing the scan results from dev5. This fixes an error case
that happened with the following test case sequence:
connect_cmd_bssid_hint connect_cmd_reject_assoc
Signed-off-by: Jouni Malinen <j@w1.fi>
The wpas (dev5) control interface socket did not always get cleared in
the MACsec test cases and this could result in issues with following
test cases if the dev5 message queue hit the maximum limit.
Signed-off-by: Jouni Malinen <j@w1.fi>
Now that the backhaul STA Multi-AP association is not rejected anymore
by the AP, update the test case to expect disconnection to be triggered
by the STA.
Signed-off-by: Arnout Vandecappelle (Essensium/Mind) <arnout@mind.be>
With just one additional argument, the run_multi_ap_association()
function can be used for all tests.
Signed-off-by: Arnout Vandecappelle (Essensium/Mind) <arnout@mind.be>
This seems to be needed when using python3 in VM for the ssid_utf8 test
case debug prints from the control interface requests. This breaks
python2 support for the same logging entries, but there does not seem to
be any easy way of addressing this in a manner that works for both
python versions, so move ahead with the python3-only support from now
on.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This test case was failing pretty frequently due to an issue in being
able to send out the Provision Discovery Response frame on the operating
channel. Now that wpa_supplicant has a fix for that issue, modify this
test case to hit this error condition every time. In addition, make sure
the possible exception from p2ps_exact_seek() does not get hidden with a
failing remove_group() call in the finally section.
Signed-off-by: Jouni Malinen <j@w1.fi>
Once mac80211 starts reporting the used Association Request frame IEs in
the association event, wpa_supplicant will update RSN supplicant IE
information based on that and that will make the AP reject EAPOL-Key msg
2/4 in this particular test scenario due to the hack of including two
RSN IEs in the Association Request frame. Accept this sequence as a
valid test execution in addition to the previously expected connection
to avoid reporting incorrect failures.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This allows unexpected cases to terminate parallel-vm.py without being
hidden by the exception handler.
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
The result of reading non blocked empty stream is different between
python2 and 3. The python2 sends "[Errno 11] Resource temporarily
unavailable" exception. The python3 could read "None" without
exception, so handle this "None" case as well.
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
In recent Debian versions, ebtables is an alias managed by
the alternatives(8) mechanism. This means /usr/sbin/ebtables
is a symlink to /etc/alternatives/ebtables, which in turn
links to the real binary.
As we mount a tmpfs over /etc, we cannot access this.
Fix this by bind-mounting the real /etc to /tmp/etc and
adding a symlink from /etc/alternatives to this.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Evidently this file must exist when running the sigma_dut
dependent tests, add it to .gitignore so it's not seen as
making the tree "unclean" when it is added manually.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
For tests, build the HS 2.0 OSU client (without browser to avoid
having webkit/curl dependencies).
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Add a test that drops the authentication frame, so that
hostapd thinks the station is unknown, and then sends one
by itself, so the station thinks it's associated. This
tests mostly the kernel's capability to recover from this
scenario.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
If telnetd is installed and --telnet <port> is passed on the
vm-run.sh command line, start a telnet server (directly connected
to bash, no login) inside the VM(s) to be able to look into them
when something is wrong. Use a user network in qemu with a single
host forward from the specified port for this, listening only on
'localhost'.
Please note that this provides unauthenticated access to the guest
system from anything that can open a TCP connection on the host system.
The guess system does have access to reading all files on the host that
the user account running kvm has access to (and even write access if the
default ROTAG ,readonly parameter is cleared). In other words, this
option should not be used on any multiuser systems where kvm is run
under user accounts that are not dedicated for testing purposes (i.e.,
do not have access to any files that should not be readable to
everyone).
This needs CONFIG_VIRTIO_NET=y in the guest kernel.
For parallel-vm.py, the --telnet argument specifies the base port
and each VM index (0, 1, ...) is added to it.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Recently, qemu/seabios grew an annoying console/terminal reset,
which also causes my terminal to be left in a state where long
lines don't work well and less gets confused because of this.
Suppress this by suppressing all output from qemu before a new
magic string printed from inside.sh.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Instead of relying on existing configuration (which may conflict
with other tests) and skipping otherwise, create a new radio with
two channels in this test and use it.
Signed-off-by: Jouni Malinen <j@w1.fi>
Instead of relying on existing configuration (which may conflict
with other tests) and skipping otherwise, create a new radio with
two channels in this test and use it.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
This is needed to fix issues with dict iteration resulting in different
order of attributes when trying to calculate Message-Authenticator
externally to pyrad.
Signed-off-by: Jouni Malinen <j@w1.fi>
All other test cases seem to work, but radius_das_disconnect_time_window
is still failing due to incorrect authenticator or Message-Authenticator
in Disconnect-Request.
Signed-off-by: Jouni Malinen <j@w1.fi>
Sending UTF-8 encoded data to logger file is currently not working
properly, so create a separate binary file with a copy of
sigma_dut-ap.conf instead to work with both python2 and python3.
Signed-off-by: Jouni Malinen <j@w1.fi>
Use struct.unpack() to get a list of int and then generate a list of
hexstr octets from it for ':'.join() to get consistent behavior for both
python2 and python3.
Signed-off-by: Jouni Malinen <j@w1.fi>
WPSAPHTTPServer class needs to explicitly decode the read value from
a bytes object to a str object.
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
Use ET.tostring() to avoid implicit bytes/str conversion issues within
ET implementation. Add XML declaration separately to match previous
behavior.
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
This is needed for python3 since the two argument version of
str.translate() is not available for unicode. Furthermore, these cases
of delete colons from the string are simple enough for replace.
Signed-off-by: Jouni Malinen <j@w1.fi>
Only python3 warns to this bug.
TypeError: '>' not supported between instances of 'type' and 'int'
Exception: '>' not supported between instances of 'type' and 'int'
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
Need to do this to avoid issues with following operations that assume
the output to be a str object.
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
Avoid implicit conversion errors when constructing bytes objects or
passing a str object to a function that needs a bytes object.
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
Signed-off-by: Jouni Malinen <j@w1.fi>
The wpas_config_file_key_mgmt fails with this error if wpa_supplicant is
built without CONFIG_SUITEB192=y:
Exception: SET_NETWORK failed
Exception: SET_NETWORK failed
Skip the WPA-EAP-SUITE-B-192 case if it is not supported in
wpa_supplicant so that the rest of the key_mgmt test coverage is
included.
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
This is needed in cases the hexlify() output is used to concatenate with
a string or used in string comparisons.
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
Signed-off-by: Jouni Malinen <j@w1.fi>
This patch is made by using 2to3 command with some modifications.
$ find . -name *.py | xargs 2to3 -f imports -w -n
Signed-off-by: Masashi Honma <masashi.honma@gmail.com>
These were not used at all and caused unnecessary operations and in some
cases, compatibility issues with python3.
Signed-off-by: Jouni Malinen <j@w1.fi>
This code is identical to the wait_event() code, except for the
mon/global_mon instance. Create a _wait_event() function that
encapsulates this, and use it for both.
While at it, fix the bug in wait_global_event() where in the case
of not having a global_mon it always returns None.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
This is useful when running a test multiple times, looking at
log output etc. to not have to pick out the right directory
each and every time.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
The wnm_sleep_mode_proto test case was already covering number of
invalid WNM-Sleep Mode Request frame cases, but it was missing the
shortest possible case with a missing Dialog Token field. Add that as a
regression test case for bounds checking in
ieee802_11_rx_wnmsleep_req().
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Since 3bdc651a62, start.sh creates the logs/current symlink even if
LOGDIR was set in the environment, as is the case when using run-all.sh.
However, run-all.sh and start.sh use a separate 'date' invocation so the
resulting string may be different. Usually it is the same because the
two invocations immediately follow each other, *except* if run-all.sh
also does a build. In addition, if the user sets LOGDIR to something
else, the symlink is completely bogus.
Fix this by not relying on the 'date' invocation for creating the
symlink. Instead, use the basename of LOGDIR. To keep things consistent
with current behavior, only create the symlink if LOGDIR points to a
subdirectory of DIR/logs.
The following use cases now work reliably:
* run-all.sh with or without the -B option;
* manually calling start.sh followed by run-tests.py without setting
LOGDIR.
* manually calling start.sh with LOGDIR set to a subdirectory of logs
and calling run-tests.py without --logdir option (which makes it
default to logs/current).
* run-all.sh with LOGDIR set to a subdirectory of logs.
Signed-off-by: Arnout Vandecappelle (Essensium/Mind) <arnout@mind.be>
This is in preparation for an implementation change that results in this
unreachable server case not incrementing radiusAuthClientAccessRequests.
Signed-off-by: Jouni Malinen <j@w1.fi>
These checks were repeated in almost every test case, so use helper
functions to get rid of duplicated (copy-pasted) code.
Signed-off-by: Jouni Malinen <j@w1.fi>
Add even more workarounds for cfg80211 regulatory state clearing since
these DFS test cases seem to be the most likely ones to fail due to
country=98 issues.
Signed-off-by: Jouni Malinen <j@w1.fi>
Add even more workarounds for cfg80211 regulatory state clearing since
these DFS test cases seem to be the most likely ones to fail due to
country=98 issues.
Signed-off-by: Jouni Malinen <j@w1.fi>
Add even more workarounds for cfg80211 regulatory state clearing since
these WNM test cases seem to be the most likely ones to fail due to
country=98 issues.
Signed-off-by: Jouni Malinen <j@w1.fi>
In addition, add even more workarounds for cfg80211 regulatory state
clearing since this test case seems to be the most likely one to fail
due to country=98 issues.
Signed-off-by: Jouni Malinen <j@w1.fi>
This is a regression test case for FT-over-DS that got broken on
mac80211-based drivers when the extra key reinstallation checks were
added.
Signed-off-by: Jouni Malinen <j@w1.fi>
ap_ft_oom seemed to depend on undesired wpa_supplicant behavior of
trying to do FT protocol even without being ready for reassociation.
This is going to be fixed in wpa_supplicant which would make this test
case fail, so split it into separate test cases for each failure item to
be able to avoid incorrect test failures.
Signed-off-by: Jouni Malinen <j@w1.fi>
The previous roam() and roam_over_ds() checks would have ignored failing
association rejection if a consecutive attempt to connect succeeds
within the initial time limit. This can miss incorrect behavior, so
check explicitly for association rejection.
Signed-off-by: Jouni Malinen <j@w1.fi>
The number of direct allocation within wpa_supplicant_mesh_init()
has been reduced due to RSN init function is factored out.
Signed-off-by: Peter Oh <peter.oh@bowerswilkins.com>
Verify that the beacon report contains the last beacon report
indication subelement when requested in the beacon request.
Signed-off-by: Avraham Stern <avraham.stern@intel.com>
Verify that when the frame body subelement causes the
measurement report element to exceed the maximum element size,
the beacon report is fragmented and the frame body fragment ID
subelement is added with the correct fragment number.
Signed-off-by: Avraham Stern <avraham.stern@intel.com>
Verify that not updating GTK (i.e., only update PTK) in the driver does
not break connectivity. This case is different after the check for
"already in-use GTK" and rejection of GTK reinstallation.
Signed-off-by: Jouni Malinen <j@w1.fi>
Use of country=00 (world roaming) seemed to not work anymore with the
current cfg80211 regulatory implementation since the existing channel is
left enabled when moving to country=00. Use a specific country code that
does enforce the selected channel from being used anymore to make this
test case pass again.
The change in cfg80211 behavior is from the kernel commit 113f3aaa81bd
("cfg80211: Prevent regulatory restore during STA disconnect in
concurrent interfaces").
Signed-off-by: Jouni Malinen <j@w1.fi>
With this command, RSSI signal can be controlled. Due to restrictions in
kernel, only values in the range of [-30, -50] can be used. The command
is implemented by changing the TX power.
Signed-off-by: Beni Lev <beni.lev@intel.com>
It was possible for the 5 GHz PKEX channels to be enabled, e.g., when
running "ap_ht40_csa2 dpp_pkex_no_responder" test sequence, and that
resulted in a failure in dpp_pkex_no_responder due to the unexpectedly
long wait needed for the DPP-FAIL event. Increase the wait time to allow
for 5 GHz PKEX channels to be probed.
Signed-off-by: Jouni Malinen <j@w1.fi>
This allows more accurate logging of failures related to the cfg80211
country=98 (intersection) case. This version is trying to give some more
time to allow the country code to clear, but that does not seem to be
sufficient with the current cfg80211 implementation for country=98 (but
might be for other cases).
The additional check for country=98 at the beginning of each test case
is an attempt to force cfg80211 to restore world roaming state with a
new association and disconnection at the station side detected after the
AP side has already stopped. This is needed after the Linux kernel
commit 113f3aaa81bd ("cfg80211: Prevent regulatory restore during STA
disconnect in concurrent interfaces").
Signed-off-by: Jouni Malinen <j@w1.fi>
This is needed to avoid leaving unexpected cfg80211 regulatory country
code in place at the point when a test case terminates.
Signed-off-by: Jouni Malinen <j@w1.fi>
Previously, the special value 0 was used to indicate no UDP checksum.
Replace that with the calculated checksum for more like use case.
Signed-off-by: Jouni Malinen <j@w1.fi>
The ap_open_tdls_vht* test cases could leave some pending regulatory
Beacon hints waiting to be cleared during the following test case. This
would result in a failure if the following test case expected specific
regdom event behavior. For example, this caused "ap_open_tdls_vht160
dbus_country" sequence to result in failure in dbus_country. Fix this by
using more robust sequence in clearing regdom state at the end of the
TDLS test cases that have the AP advertising a country code.
Signed-off-by: Jouni Malinen <j@w1.fi>
Not all driver interfaces provide driver status information with the
local address, so skip the override step if the field is not available.
This is needed, e.g., with macsec_linux.
Signed-off-by: Jouni Malinen <j@w1.fi>
Add a new test to check that the AP won't send frames to the client if
it tries to talk to itself.
Note that this fails until the relevant mac80211 patch is merged.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
These test cases seemed to have copy-paste errors where
wait_enabled=False was forgotten even though there was no additional
steps checking the AP mode startup results. This did not break the
tests, but could have resulted in slowing them down if the STAs did not
find the AP in the first scan.
Signed-off-by: Jouni Malinen <j@w1.fi>
The Linux kernel commit 113f3aaa81bd ("cfg80211: Prevent regulatory
restore during STA disconnect in concurrent interfaces") broke the
regulatory clearing attempt in many test cases since
cfg80211_is_all_idle() is now returning false due to the AP interface
being up and that results in the Country IE -based regulatory
information not getting cleared back to defaults.
Work around this by stopping the AP interface first so that when the
station interface receives the disconnection, there are no other active
interfaces in the system. In addition, wait for REGDOM event for the
Country IE hint after association to avoid disconnection before the
regulatory events have been fully processed.
Signed-off-by: Jouni Malinen <j@w1.fi>
The Linux kernel commit 113f3aaa81bd ("cfg80211: Prevent regulatory
restore during STA disconnect in concurrent interfaces") broke the
regulatory clearing attempt in this test case since
cfg80211_is_all_idle() is now returning false due to the AP interface
being up and that results in the Country IE -based regulatory
information not getting cleared back to defaults.
Work around this by stopping the AP interface first so that when the
station interface receives the disconnection, there are no other active
interfaces in the system. In addition, wait for REGDOM event for the
Country IE hint after association to avoid disconnection before the
regulatory events have been fully processed.
Signed-off-by: Jouni Malinen <j@w1.fi>
cfg80211 regulatory code gets into pretty inconvenient state if it needs
to intersect regulatory domain information from multiple regulations
(country=98). The existing mechanisms in the hwsim test cases are not
able to clear that up for the following test case and this can result in
large number of failures.
It looks like country=98 case is hit frequently in WNM test cases where
a station associates with an AP that advertises a specific country code
and that station is then asked to disconnect before the REGDOM events
have been received. Avoid this by waiting for the REGDOM events for the
init=COUNTRY_IE case before disconnecting.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This adds some minimal testing for Multi-BSS connection attempts. The
part for nontransmitted BSS is limited since hostapd/mac80211 does not
yet have sufficient support for Multi-BSS in AP mode.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Perform detailed tests with OCV enabled, for both the 4-way and group
key handshakes. These tests include establishing a working connection
with OCV enabled, assuring that a STA without OCV enabled can still
connect to a STA with OCV enabled (and vice versa), verifying that
invalid OCI elements get silently ignored, verifying that missing OCI
elements are reported, and so on.
Signed-off-by: Mathy Vanhoef <Mathy.Vanhoef@cs.kuleuven.be>
parallel-vm.py has obsoleted this a long time ago and there is no need
to maintain two scripts for doing more or less the same thing.
Signed-off-by: Jouni Malinen <j@w1.fi>
Now that hostapd starts mandating PMF for Hotspot 2.0 Release 2
association, this test case needs some more tweaks to work. Hardcode
Hotspot 2.0 Release 1 to be used and disable PMF explicitly.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The Beacon loss event was not reported anymore, so remove that as an
unnecessary step in the test case. In addition, check the key_mgmt
values explicitly.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This is needed to meet the Hotspot 2.0 Release 2 requirement for the
third station that is actually using RSN.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Match the implementation change to fix the test cases that verified a
specific Hotspot 2.0 release number indication.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This is a regression test case for a potential NULL pointer
dereferencing fixed in the previous commit.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>