time-travel=inf-cpu needs bit more wait before being able to fetch the
STATUS* items after initial connection request.
Signed-off-by: Jouni Malinen <j@w1.fi>
Waiting for exactly one second for a one second timeout with
time-travel=inf-cpu is not exactly robust, so increase that wait to be
able to see the last EAPOL-Key TX attempt from hostapd.
Signed-off-by: Jouni Malinen <j@w1.fi>
Busy loop for waiting is not going to work with time-travel=inf-cpu, so
need to something a bit more explicit to wait for the wpa_supplicant
process to proceed while not fully breaking the idea of this test case
to iteration through large number of STATUS-VERBOSE commands to hit
different states.
Signed-off-by: Jouni Malinen <j@w1.fi>
The sae_groups parameter needs to be cleared before attempt a SAE
connection in a test case to avoid issues with this parameter having
been left to something else than the default one by a previous test
case. This was found with the following sequence:
sae_pwe_failure dpp_auto_connect_legacy_psk_sae_1
Signed-off-by: Jouni Malinen <j@w1.fi>
The earlier change from using apdev[1] to using a no-interface
ifname=as-erp in the ERP related test cases ended up leaving the
separate authentication server interface running after the end of the
test case. This left UDP port 18128 open and any consecutive test case
needing this port failed to start another authentication server.
This can be reproduced with following test case sequence:
fils_auth_gtk_rekey authsrv_unknown_user
Fixes: e374def207 ("tests: Start ERP authentication server without AP")
Signed-off-by: Jouni Malinen <j@w1.fi>
There is no actual need for running the authentication server with
driver=nl80211, so simplify this by using driver=none instead. This
frees up apdev[1] for actual AP needs in the test cases.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This speeds up test execution significantly by removing unnecessary
waiting for things to happen since the kernel log is allowed to jump
forward whenever there is nothing to do.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This test case was failing frequently due to the station not being able
to connect back to the AP if the interrupted channel switch ended up
moving the AP to the new channel anyway on restart. Scan both possible
channels to allow the AP to be found in either case.
Signed-off-by: Jouni Malinen <j@w1.fi>
This allows UML builds to be used in running user mode without having to
run the full x86 kernel in virtual machine.
Signed-off-by: Jouni Malinen <j@w1.fi>
The change to use a shared dragonfly_generate_scalar() helper function
resulted in failures in sae_no_random and sae_bignum_failure test cases
due to renamed functions and removed uses.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The change to use shared dragonfly_get_random_qr_qnr() and
dragonfly_get_rand_1_to_p_1() helper functions resulted in failures in
sae_no_random and sae_bignum_failure test cases due to renamed functions
and removed uses.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
dbus_p2p_go_neg_init, dbus_p2p_group_idle_timeout, and
dbus_p2p_group_termination_by_go could end up print a "DETACH failed"
exception as a warning from WpaSupplicant.__del__ for the dev1 instance
used within the TestDbusP2p class. This did not cause the test cases to
fail, but the output is a bit confusing, so clean this up be explicitly
closing the control interface monitor sockets and furthermore by
ignoring the "DETACH failed" exception within __del__.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This is in preparation of disallowing all use of these groups. Negative
test case for the groups will be added in a separate commit after the
implementation has been changed.
Signed-off-by: Jouni Malinen <j@w1.fi>
It looks like the scan operation could end up reverting regdom back to
the previously configured one, so configure 00 country before starting
the disconnect-and-stop-scan operation to give some more time for the
regdom to be cleared.
Signed-off-by: Jouni Malinen <j@w1.fi>
The last beacon report indication was set in all the beacon report
elements in the last frame of the beacon report, while it should be set
only in the last beacon report element of the last frame. This is now
fixed in wpa_supplicant, so update the test case expectation to match
the fixed behavior.
Signed-off-by: Avraham Stern <avraham.stern@intel.com>
The change to python3 broke trace-cmd recording, two
strings need to be bytes instead. Fix that.
Also add a flush() that seems to be needed now.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
This makes it easier to test various X.509 certificate validation steps
with the server certificate being generated and signed using pyOpenSSL
dynamically.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
cfg80211 was modified to allow the Multiple BSSID Index element to be
included in the IEs for a nontransmitted BSS. Update the validation step
in this test case to allow that different with the IEs in the Beacon
frame (transmitted BSS).
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Reduce testing dependency on the unsuitable groups so that a test case
against a production build would not fail the test case unnecessarily.
This is in preparation of making production builds
(CONFIG_TESTING_OPTIONS not defined) of wpa_supplicant hostapd disable
all DH groups that have been indicated as being unsuitable.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
FLUSH should be done on P2P device interface, otherwise the networks are
not removed. Fix that.
Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
The separate dpp_bootstrap_gen() functions were merged into a single
one, so the test case needs a matching change to avoid failures.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Increase testing coverage by going through all six possible curves with
full provisioning of AP and STA and connection (which includes PFS with
DPP2).
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This test case did not clear a possibly modified sae_groups value from a
prior test case for adev[2] and could fail if the previously set group
was not supported by the AP.
Signed-off-by: Jouni Malinen <j@w1.fi>
These test cases did not clear a possibly modified sae_groups value from
a prior test case and could fail if the previously set group was not
supported by the AP.
Signed-off-by: Jouni Malinen <j@w1.fi>
This test case did not clear a possibly modified sae_groups value from a
prior test case and could fail if the previously set group was not
supported by the AP.
Signed-off-by: Jouni Malinen <j@w1.fi>
Use a helper function to perform this common sequence to disconnect and
stop any possibly started reconnection attempt.
Signed-off-by: Jouni Malinen <j@w1.fi>
If the ABORT_SCAN command succeeds, CTRL-EVENT-SCAN-RESULTS event is
delivered for the aborted scan. Following this with an immediate
flush_scan_cache() call can result in the first scan interpreting that
pending event as the completion and that results in trying to start
another scan while the first scan is still in progress.
Signed-off-by: Jouni Malinen <j@w1.fi>
This is needed to avoid leaving behind a ROC operation at the end of the
test case. This was found with the following test sequence:
p2p_ext_vendor_elem_invitation wifi_display_r2
Signed-off-by: Jouni Malinen <j@w1.fi>
Parsing of the DER encoded signature was unable to handle results that
were shorter than the prime. These need to be zero padded from left to
generate the correct value.
Signed-off-by: Jouni Malinen <j@w1.fi>
The long wait for the monitor socket events resulted in another socket
running out of TX buffer space. Split the wait into smaller segments and
clear the other socket in each iteration.
Signed-off-by: Jouni Malinen <j@w1.fi>
Do not leave all the event messages pending in the socket queue for the
full duration of the test case to avoid hitting the TX socket queue
limit.
Signed-off-by: Jouni Malinen <j@w1.fi>
Some of the test cases left behind attached control interface monitor
sockets that could result in hitting the wpa_supplicant socket TX queue
limit. Try to be a bit more careful about detaching and closing the
sockets to avoid this.
Signed-off-by: Jouni Malinen <j@w1.fi>
The "_ipv6" part of the file name was missing and this resulted in file
names that conflicted with the IPv4 test cases and could overwrite logs
for those.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
It does not look like there would be two CTRL-EVENT-ASSOC-REJECT events
here, so only check the first one instead of requiring both to be
received with status_code=27. This test case could fail based on the
second connection attempt (due to that extra event wait) timing out.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Print a list of full paths to log files from failed test cases both the
parallel.log and stdout so that they can be easily opened for analysis.
In addition, renumber the VM lines in the <timestamp>-parallel.log to
match the i+1 numbering used in the log directories and UI that is
tracking test execution.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
One of the steps that expected failure due to PMKID mismatch did not
stop connection attempts. This could result in the following test step
failing due to the previous profile with peaplabel=1 getting used to
derive the MSK incorrectly.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The wait_event() call for scan completion could have processed a
previously received event from a prior scan instead of the newly started
one. This could result in flush_scan_cache() assuming there are still
results in the cache even though the scan request to clear the cache had
not even be started yet.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Use more readable "foo not in bar" construction for the couple of places
that did "not foo in bar".
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Prior cleanup broke the indentation here and made the addition of test
cases unreachable.
Fixes: 0663ae22ff ("tests: Do not use tabs for indentation")
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The new DPP Configuration Result message can result in a bit different
behavior at the end of the configuration exchange and some of the test
cases need more flexibility to work with that DPP2 behavior.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
gas_address3 was set to 1 in this test case, but it was never cleared.
That can result in unexpected behavior in other test cases that dpeends
on gas_address3 being in its default value 0. Clear the parameter
explicitly to avoid this.
This resulted in an error in the following test sequence:
dpp_qr_code_auth_initiator_enrollee gas_anqp_address3_ap_forced
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
There was a race condition on starting the flush_scan_cache() operations
if a scan happened to be in progress when the test case ended since the
ABORT_SCAN success case did not wait for the pending scan operation to
be completed. Wait for the scan completion event in addition to the
disconnection event if the ABORT_SCAN command is accepted.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
There was a race condition on starting the flush_scan_cache() operations
if a scan happened to be in progress when the test case ended since the
ABORT_SCAN success case did not wait for the pending scan operation to
be completed. Wait for the scan completion event in addition to the
disconnection event if the ABORT_SCAN command is accepted.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
These TDLS test cases missed Popen() result decode() calls in the
earlier python3 compatibility changes. Add those to make debug log more
readable.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Wait explicitly for the DPP-NOT-COMPATIBLE event when going through
protocol testing with local failures instead of just waiting for a fixed
0.1 second duration. This prevents a test failure at least in
dppauth_resp_status_failure in a case where the failing operation may be
delayed under heavy CPU load.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Test case sequence "ap_wps_ap_scan_2 ap_wps_pbc_2ap" resulted in a
failure due to a scan entry being left behind from the first test case
and the second one ending up using that obsolete result during WPS_PBC
processing. Fix this by clearing the scan results explicitly on dev5.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Accept a smaller number of token responses in second round to avoid
failing this test case as frequently.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The configurated fragmentation/RTS threshold value survives AP mode
interface restarts, so these values need to be explicitly cleared back
to default (disabled). This fixes an issue where some test cases could
not work correctly if fragmentation on the interface was enabled. For
example, this combination used to fail:
ap_fragmentation_open ap_hs20_fetch_osu
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The first scan for the unknown BSSID could have been timed in a manner
that allows passive scanning to find the real AP even if that AP's
beacon interval was 1000 (e.g., heavy CPU load changed timing so that
the AP beaconing started at suitable time). The check for BSS result
entry not including Probe Response frame was comparing incorrect BSS
entries (bss2 vs. bss1) which resulted in the test case claiming failure
even when there was no unexpected Probe Response frame.
Fix this by comparing the beacon_ie and ie parameters from the same BSS
entry (bss1).
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Number of these test cases start connection attempt in wpa_supplicant
and then expected a specific failure to happen relatively quickly. This
could result in timeouts if the first scanning round missed to find the
AP (e.g., due to CPU load pushing out the Probe Response frame long
enough for the station having left the channel) and wpa_supplicant then
waiting five seconds before starting a new scan.
Make this more robust by scanning explicitly for the specific BSSID
before starting the connection attempt.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This old interface has been obsoleted and should not have been used
since 2010, so remove testing for it in preparation to dropping the
interface completely from wpa_supplicant.
Signed-off-by: Lubomir Rintel <lkundrak@v3.sk>
No need to duplicate this functionality when all the ap_ft_pmf_*_over_ds
test cases are doing practically the same thing and the
no-specific-cipher-configuration case can be addressed easily with the
same helper function.
Signed-off-by: Jouni Malinen <j@w1.fi>
The main step of the test case was accidentally removed when adding the
cipher specific versions.
Fixes: ffcaca68d3 ("tests: FT with different BIP algorithms")
Signed-off-by: Jouni Malinen <j@w1.fi>