Commit graph

3184 commits

Author SHA1 Message Date
Jouni Malinen
78ed42d8a2 tests: ERP/FILS with external hostapd process as RADIUS server
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-04-06 16:47:38 +03:00
Jouni Malinen
d08ef5798d tests: sigma_dut controlled AP with PSK, SAE, FT
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-04-01 13:28:26 +03:00
Jouni Malinen
659f7954f4 tests: WPA2-EAP-FT with SHA384 using REASSOCIATE
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-28 01:57:10 +02:00
Jouni Malinen
1211031a60 tests: WPA2-FT-SAE AP and PMKSA caching for initial MD association
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-27 04:04:16 +02:00
Jouni Malinen
43f68853ab tests: sigma_dut controlled SAE association with Password Identifier/FT
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-26 22:50:17 +02:00
Jouni Malinen
cdf5391013 tests: SAE + FT-SAE configuration
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-26 22:50:17 +02:00
Jouni Malinen
1b232c1b96 tests: sigma_dut and SAE Password Identifier
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-26 22:50:17 +02:00
Jouni Malinen
5be5b81678 tests: dpp_bootstrap_gen_failures to match implementation changes
The separate dpp_bootstrap_gen() functions were merged into a single
one, so the test case needs a matching change to avoid failures.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-24 17:29:45 +02:00
Jouni Malinen
74cb18c6b0 tests: sigma_dut sta_scan GetParameter,SSID_BSSID
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-23 12:50:46 +02:00
Jouni Malinen
7f1eeda2df tests: Reset sae_groups in sigma_dut_dpp_qr_init_enrollee_sae
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-18 19:00:06 +02:00
Jouni Malinen
f9bac0f6b3 tests: Remove unnecessary dump_monitor() calls from end of test cases
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-18 18:32:31 +02:00
Jouni Malinen
e105110f40 tests: Use a helper function for DPP_CONFIGURATOR_ADD/REMOVE
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-18 18:32:31 +02:00
Jouni Malinen
5725b3e355 tests: Use a helper function for DPP_AUTH_INIT
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-18 18:32:31 +02:00
Jouni Malinen
84438350ae tests: DPP AP+STA provisioning and connection with Brainpool curves
Increase testing coverage by going through all six possible curves with
full provisioning of AP and STA and connection (which includes PFS with
DPP2).

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-18 18:32:31 +02:00
Jouni Malinen
e71a90711d tests: Fix mesh_sae_groups_invalid to reset sae_groups setting
This test case did not clear a possibly modified sae_groups value from a
prior test case for adev[2] and could fail if the previously set group
was not supported by the AP.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-18 00:02:16 +02:00
Jouni Malinen
96ad141e6c tests: Fix WPS with SAE test cases to reset sae_groups setting
These test cases did not clear a possibly modified sae_groups value from
a prior test case and could fail if the previously set group was not
supported by the AP.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-18 00:02:11 +02:00
Jouni Malinen
95ace8670b tests: Fix ap_mixed_security to reset sae_groups setting
This test case did not clear a possibly modified sae_groups value from a
prior test case and could fail if the previously set group was not
supported by the AP.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-18 00:02:08 +02:00
Jouni Malinen
296670aa94 tests: ap_mixed_security to use SAE capability from the correct station
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-17 21:38:34 +02:00
Jouni Malinen
203878d797 tests: Helper function for checking DPP-FAIL reporting
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-17 20:58:44 +02:00
Jouni Malinen
6d196e5928 tests: Helper functions for DPP PKEX initiator and responder
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-17 20:57:58 +02:00
Jouni Malinen
517f76b158 tests: DPP use the wait_auth_success() helper function
Use the already existing helper function and extend it to cover the most
common test sequences.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-17 19:17:31 +02:00
Jouni Malinen
7e0091007c tests: Use helper function for DPP_LISTEN commands
Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-17 18:19:58 +02:00
Jouni Malinen
e01a492caa tests: Helper function for DISCONNECT + ABORT_SCAN + wait
Use a helper function to perform this common sequence to disconnect and
stop any possibly started reconnection attempt.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-17 17:58:33 +02:00
Jouni Malinen
2b4263d06f tests: Handle scan result clearing more carefully in ap_country
If the ABORT_SCAN command succeeds, CTRL-EVENT-SCAN-RESULTS event is
delivered for the aborted scan. Following this with an immediate
flush_scan_cache() call can result in the first scan interpreting that
pending event as the completion and that results in trying to start
another scan while the first scan is still in progress.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-17 17:40:39 +02:00
Jouni Malinen
09bdbc6ed9 tests: Remove group at the end of p2p_ext_vendor_elem_invitation
This is needed to avoid leaving behind a ROC operation at the end of the
test case. This was found with the following test sequence:
p2p_ext_vendor_elem_invitation wifi_display_r2

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-17 17:06:04 +02:00
Jouni Malinen
421d658a67 tests: Fix ECDSA signature generation
Parsing of the DER encoded signature was unable to handle results that
were shorter than the prime. These need to be zero padded from left to
generate the correct value.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-17 16:53:05 +02:00
Jouni Malinen
3a88b7e6e9 tests: Split event wait in grpform_cred_ready_timeout
The long wait for the monitor socket events resulted in another socket
running out of TX buffer space. Split the wait into smaller segments and
clear the other socket in each iteration.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-17 16:08:53 +02:00
Jouni Malinen
e4b4e1748a tests: Clear monitor socket queue in ap_hs20_interworking_oom
Do not leave all the event messages pending in the socket queue for the
full duration of the test case to avoid hitting the TX socket queue
limit.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-17 16:08:31 +02:00
Jouni Malinen
b21540e682 tests: Close wpa_supplicant control interface more robustly
Some of the test cases left behind attached control interface monitor
sockets that could result in hitting the wpa_supplicant socket TX queue
limit. Try to be a bit more careful about detaching and closing the
sockets to avoid this.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-17 16:08:30 +02:00
Jouni Malinen
4d916a7f3e tests: Fix dump_monitor() without monitor attached
Do not try to dump pending event messages if the monitor socket has not
been attached.

Signed-off-by: Jouni Malinen <j@w1.fi>
2019-03-17 12:22:23 +02:00
Jouni Malinen
fab49f6145 tests: Python coding style cleanup (pylint3 bad-whitespace)
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-16 18:52:09 +02:00
Jouni Malinen
009b54bedd tests: DPP and provisoning DPP and legacy AKMs
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-16 18:52:09 +02:00
Jouni Malinen
3e1cfead0b tests: Use matching prefix for the ProxyARP IPv6 log files
The "_ipv6" part of the file name was missing and this resulted in file
names that conflicted with the IPv4 test cases and could overwrite logs
for those.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-15 23:57:44 +02:00
Jouni Malinen
39139d7ead tests: Decode brctl showmacs output for the debug log
This is needed with python3 to make the debug log more readable.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-15 23:57:44 +02:00
Jouni Malinen
649038e117 tests: Remove unnecessary second wait from connect_cmd_reject_assoc
It does not look like there would be two CTRL-EVENT-ASSOC-REJECT events
here, so only check the first one instead of requiring both to be
received with status_code=27. This test case could fail based on the
second connection attempt (due to that extra event wait) timing out.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-15 23:57:44 +02:00
Jouni Malinen
a2d300765b tests: Make parallel-vm.py log easier to use for debugging failures
Print a list of full paths to log files from failed test cases both the
parallel.log and stdout so that they can be easily opened for analysis.
In addition, renumber the VM lines in the <timestamp>-parallel.log to
match the i+1 numbering used in the log directories and UI that is
tracking test execution.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-15 21:10:00 +02:00
Jouni Malinen
8cfc758827 tests: Make ap_wpa2_eap_peap_params more robust
One of the steps that expected failure due to PMKID mismatch did not
stop connection attempts. This could result in the following test step
failing due to the previous profile with peaplabel=1 getting used to
derive the MSK incorrectly.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-15 13:51:55 +02:00
Jouni Malinen
043a29ecc4 tests: Clear pending monitor events before starting scan
The wait_event() call for scan completion could have processed a
previously received event from a prior scan instead of the newly started
one. This could result in flush_scan_cache() assuming there are still
results in the cache even though the scan request to clear the cache had
not even be started yet.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-15 13:51:55 +02:00
Jouni Malinen
4131ba5c55 tests: External radio work and DISCONNECT clearing connection attempt
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-15 13:03:31 +02:00
Jouni Malinen
a8b8da1132 tests: Python coding style cleanup (pylint3 unneeded-not)
Use more readable "foo not in bar" construction for the couple of places
that did "not foo in bar".

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-15 11:34:32 +02:00
Jouni Malinen
2f22ed4fab tests: Fix run-tests.py module file (-l) handling
Prior cleanup broke the indentation here and made the addition of test
cases unreachable.

Fixes: 0663ae22ff ("tests: Do not use tabs for indentation")
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-15 11:18:20 +02:00
Jouni Malinen
3507968fd2 tests: SAE anti-clogging request with mesh BSS
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-15 00:31:09 +02:00
Jouni Malinen
8ad1009e50 tests: DPP and Enrollee rejecting Config Object
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-15 00:31:09 +02:00
Jouni Malinen
8b6c834ff9 tests: DPP test cases to handle new behavior due to config result
The new DPP Configuration Result message can result in a bit different
behavior at the end of the configuration exchange and some of the test
cases need more flexibility to work with that DPP2 behavior.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-15 00:31:09 +02:00
Jouni Malinen
f77d106294 tests: Fix dpp_qr_code_auth_initiator_enrollee to clear gas_address3
gas_address3 was set to 1 in this test case, but it was never cleared.
That can result in unexpected behavior in other test cases that dpeends
on gas_address3 being in its default value 0. Clear the parameter
explicitly to avoid this.

This resulted in an error in the following test sequence:
dpp_qr_code_auth_initiator_enrollee gas_anqp_address3_ap_forced

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-14 00:13:35 +02:00
Jouni Malinen
86db4e63d3 tests: Make WNM test case scan clearing more robust
There was a race condition on starting the flush_scan_cache() operations
if a scan happened to be in progress when the test case ended since the
ABORT_SCAN success case did not wait for the pending scan operation to
be completed. Wait for the scan completion event in addition to the
disconnection event if the ABORT_SCAN command is accepted.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-13 23:33:41 +02:00
Jouni Malinen
64766a7783 tests: Make TDLS test case scan clearing more robust
There was a race condition on starting the flush_scan_cache() operations
if a scan happened to be in progress when the test case ended since the
ABORT_SCAN success case did not wait for the pending scan operation to
be completed. Wait for the scan completion event in addition to the
disconnection event if the ABORT_SCAN command is accepted.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-13 23:33:21 +02:00
Jouni Malinen
32e4ad4433 tests: Decode station dump output to restore pre-python3 behavior
These TDLS test cases missed Popen() result decode() calls in the
earlier python3 compatibility changes. Add those to make debug log more
readable.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-13 20:40:31 +02:00
Jouni Malinen
3d5cfa0f6d tests: Make DPP protocol failure testing more robust
Wait explicitly for the DPP-NOT-COMPATIBLE event when going through
protocol testing with local failures instead of just waiting for a fixed
0.1 second duration. This prevents a test failure at least in
dppauth_resp_status_failure in a case where the failing operation may be
delayed under heavy CPU load.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-13 19:44:50 +02:00
Jouni Malinen
8b944cf779 tests: Clear scan results from dev5 in WPS testing
Test case sequence "ap_wps_ap_scan_2 ap_wps_pbc_2ap" resulted in a
failure due to a scan entry being left behind from the first test case
and the second one ending up using that obsolete result during WPS_PBC
processing. Fix this by clearing the scan results explicitly on dev5.

Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
2019-03-13 19:27:21 +02:00