dbus_p2p_go_neg_init, dbus_p2p_group_idle_timeout, and
dbus_p2p_group_termination_by_go could end up print a "DETACH failed"
exception as a warning from WpaSupplicant.__del__ for the dev1 instance
used within the TestDbusP2p class. This did not cause the test cases to
fail, but the output is a bit confusing, so clean this up be explicitly
closing the control interface monitor sockets and furthermore by
ignoring the "DETACH failed" exception within __del__.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This is in preparation of disallowing all use of these groups. Negative
test case for the groups will be added in a separate commit after the
implementation has been changed.
Signed-off-by: Jouni Malinen <j@w1.fi>
It looks like the scan operation could end up reverting regdom back to
the previously configured one, so configure 00 country before starting
the disconnect-and-stop-scan operation to give some more time for the
regdom to be cleared.
Signed-off-by: Jouni Malinen <j@w1.fi>
The last beacon report indication was set in all the beacon report
elements in the last frame of the beacon report, while it should be set
only in the last beacon report element of the last frame. This is now
fixed in wpa_supplicant, so update the test case expectation to match
the fixed behavior.
Signed-off-by: Avraham Stern <avraham.stern@intel.com>
The change to python3 broke trace-cmd recording, two
strings need to be bytes instead. Fix that.
Also add a flush() that seems to be needed now.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
This makes it easier to test various X.509 certificate validation steps
with the server certificate being generated and signed using pyOpenSSL
dynamically.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
cfg80211 was modified to allow the Multiple BSSID Index element to be
included in the IEs for a nontransmitted BSS. Update the validation step
in this test case to allow that different with the IEs in the Beacon
frame (transmitted BSS).
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Reduce testing dependency on the unsuitable groups so that a test case
against a production build would not fail the test case unnecessarily.
This is in preparation of making production builds
(CONFIG_TESTING_OPTIONS not defined) of wpa_supplicant hostapd disable
all DH groups that have been indicated as being unsuitable.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
FLUSH should be done on P2P device interface, otherwise the networks are
not removed. Fix that.
Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@intel.com>
The separate dpp_bootstrap_gen() functions were merged into a single
one, so the test case needs a matching change to avoid failures.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Increase testing coverage by going through all six possible curves with
full provisioning of AP and STA and connection (which includes PFS with
DPP2).
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
This test case did not clear a possibly modified sae_groups value from a
prior test case for adev[2] and could fail if the previously set group
was not supported by the AP.
Signed-off-by: Jouni Malinen <j@w1.fi>
These test cases did not clear a possibly modified sae_groups value from
a prior test case and could fail if the previously set group was not
supported by the AP.
Signed-off-by: Jouni Malinen <j@w1.fi>
This test case did not clear a possibly modified sae_groups value from a
prior test case and could fail if the previously set group was not
supported by the AP.
Signed-off-by: Jouni Malinen <j@w1.fi>
Use a helper function to perform this common sequence to disconnect and
stop any possibly started reconnection attempt.
Signed-off-by: Jouni Malinen <j@w1.fi>
If the ABORT_SCAN command succeeds, CTRL-EVENT-SCAN-RESULTS event is
delivered for the aborted scan. Following this with an immediate
flush_scan_cache() call can result in the first scan interpreting that
pending event as the completion and that results in trying to start
another scan while the first scan is still in progress.
Signed-off-by: Jouni Malinen <j@w1.fi>
This is needed to avoid leaving behind a ROC operation at the end of the
test case. This was found with the following test sequence:
p2p_ext_vendor_elem_invitation wifi_display_r2
Signed-off-by: Jouni Malinen <j@w1.fi>
Parsing of the DER encoded signature was unable to handle results that
were shorter than the prime. These need to be zero padded from left to
generate the correct value.
Signed-off-by: Jouni Malinen <j@w1.fi>
The long wait for the monitor socket events resulted in another socket
running out of TX buffer space. Split the wait into smaller segments and
clear the other socket in each iteration.
Signed-off-by: Jouni Malinen <j@w1.fi>
Do not leave all the event messages pending in the socket queue for the
full duration of the test case to avoid hitting the TX socket queue
limit.
Signed-off-by: Jouni Malinen <j@w1.fi>
Some of the test cases left behind attached control interface monitor
sockets that could result in hitting the wpa_supplicant socket TX queue
limit. Try to be a bit more careful about detaching and closing the
sockets to avoid this.
Signed-off-by: Jouni Malinen <j@w1.fi>
The "_ipv6" part of the file name was missing and this resulted in file
names that conflicted with the IPv4 test cases and could overwrite logs
for those.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
It does not look like there would be two CTRL-EVENT-ASSOC-REJECT events
here, so only check the first one instead of requiring both to be
received with status_code=27. This test case could fail based on the
second connection attempt (due to that extra event wait) timing out.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Print a list of full paths to log files from failed test cases both the
parallel.log and stdout so that they can be easily opened for analysis.
In addition, renumber the VM lines in the <timestamp>-parallel.log to
match the i+1 numbering used in the log directories and UI that is
tracking test execution.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
One of the steps that expected failure due to PMKID mismatch did not
stop connection attempts. This could result in the following test step
failing due to the previous profile with peaplabel=1 getting used to
derive the MSK incorrectly.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The wait_event() call for scan completion could have processed a
previously received event from a prior scan instead of the newly started
one. This could result in flush_scan_cache() assuming there are still
results in the cache even though the scan request to clear the cache had
not even be started yet.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Use more readable "foo not in bar" construction for the couple of places
that did "not foo in bar".
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
Prior cleanup broke the indentation here and made the addition of test
cases unreachable.
Fixes: 0663ae22ff ("tests: Do not use tabs for indentation")
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
The new DPP Configuration Result message can result in a bit different
behavior at the end of the configuration exchange and some of the test
cases need more flexibility to work with that DPP2 behavior.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
gas_address3 was set to 1 in this test case, but it was never cleared.
That can result in unexpected behavior in other test cases that dpeends
on gas_address3 being in its default value 0. Clear the parameter
explicitly to avoid this.
This resulted in an error in the following test sequence:
dpp_qr_code_auth_initiator_enrollee gas_anqp_address3_ap_forced
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
There was a race condition on starting the flush_scan_cache() operations
if a scan happened to be in progress when the test case ended since the
ABORT_SCAN success case did not wait for the pending scan operation to
be completed. Wait for the scan completion event in addition to the
disconnection event if the ABORT_SCAN command is accepted.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
There was a race condition on starting the flush_scan_cache() operations
if a scan happened to be in progress when the test case ended since the
ABORT_SCAN success case did not wait for the pending scan operation to
be completed. Wait for the scan completion event in addition to the
disconnection event if the ABORT_SCAN command is accepted.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>
These TDLS test cases missed Popen() result decode() calls in the
earlier python3 compatibility changes. Add those to make debug log more
readable.
Signed-off-by: Jouni Malinen <jouni@codeaurora.org>